Laserfiche WebLink
6. ICC/ANSI A 117.1-2003 requires 98 inches of vertical clearance throughout the route to a <br /> van accessible pazking space. <br /> 7. Please provide dimensions and detailing to confirm compliance with the transfer-type <br /> shower and maneuverability requirements of 608.2 of ANSI A 117.1. <br /> 8. The stainvay must be reconfigumd to provide handrail extensions on both sides at tl�e top <br /> and bottom of the system. Also the handrail extension details should be clarified to show <br /> compliance with IBC 1012.5. <br /> 9. Section 502.7 of ANS[ Al 17.1 mquires a dimension of 60 inches minimum from the <br /> bottom of the accessible pazking space sign to the parking surface. <br /> [f you have any questions, please call me at 425-257-72ti4. <br /> Please providc a response letter showing where each item in this correction letter is addressed on <br /> the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and pian review will <br /> recommence. <br /> All required submittals shall be of suflicient detail and contain sufficient infortnation to ensure <br /> that thc proposed structure will be constructed in compliance with all adopted codes. <br /> Sinccrely, �,\ <br /> �'��� <br /> Stevc Millcr <br /> Associatc Gnginecr <br /> � <br /> leiM1>�millaTlO?Lnti1101n1'�abc 4.d <br />