l <br /> 9. Fire Aiazm System - An approved automatic fue detection system shall be provided as required <br /> by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. Plans for such <br /> system shall be submitted to the Fire Code Official for review and apptoval prior to installation. <br /> Submittal shall include cut sheets of all equipment intended for use. Appropriate trip tests, witnessed <br /> by a Fire Department Inspector, shall be performed, atong with a certi5cate of completion, prior to <br /> final acceptance of the system. Fire alarm syscems shall be installed according to NFPA Chapter 72. <br /> Installetion of fim alarm components, including basic wiring, may not commence before plans <br /> are approved by lhe Firc Department Plan Reviewer. Fire alarm drawings must be professionally <br /> rendered, in sufficient detail, and must be internally consistent. Riser diagrams must match <br /> ins[allation plans and load calculations. Components must be listcd and approved for use togcther. <br /> Changes to plans must inciude new drawings and caiculations and must be approved by the Fire <br /> Department Plan Reviewer prior to installation. Fire alarm installation is subject to field inspectiun by <br /> a Fire Dcpartrncnt Inspector. An approved set of plans and the Engineering & Public Services <br /> Department electrical permit must be present for any installation inspection. Fire alarm systems shall <br /> be installed undcr p�r mit of thc City of Evcrctt Gnginecring & Public Services Department. Electrical <br /> inspections and approval arc rcyuired prior to exlling for acceptance tests. Call (425) 257-8810 fo: <br /> permit information. T6c absence oT workiog phone lines for the alarm system will be cause for <br /> postponing Fire Deparlment inspection and testing and shall result in denial of occupancy. <br /> ]0. Fire Su�ression��rinkler) System - An approved automatic suppression system shall be <br /> provided as required by City Ordinance No. 3021-07, Chapter 16.76, of thc Everett Municipal Codc. <br /> The system musl include a mechunical waler gong bell. Plans for any such system shall be <br /> submitted to the Lngineering & Public Services Department for examination and approval. Such plans <br /> shall indude plans for the undcrground mains that will supply thc sprinklet system. The type of <br /> sprinkler to be installed will bc determined by the Building Official. it may be an NFPA 13, NFPA <br /> 13R, or NI�hA 13D system depending upon several factors. Sprinkler installation shell not begin <br /> without an upproved und stamped set of plans fram the Engineering & Public Services <br /> Deparlmenl. The Pire Deparmient will also review the plans and shall ficld inspect the installation <br /> based only on approved plans that nmst bc on sitc. Changes to plans must be approved by both the <br /> G��gineering & Public Services and !'ire Departments. AUoveground sprinkler piping shall be <br /> hydrostatically tested as establisl�ed in NFPA Standard 13. Undergtound piping shall be <br /> hydrostaticalty tested and tlushed as established in NPPA Standard 24 for private tire mains. clow- <br /> ground aipin� must bc installcd bv �'ashinEton Slatc Patrol I.icenscd Undcreround Sprinklcr <br /> line cerlified "U" installcrs. Nor furlhcr information, cuntacl lhe Stale Fire Marshal's Officc at <br /> (3G0) 570-3134 or contacl lhe F,verett Ein Department at (425) 257-8124.) All such tests shrll be <br /> witncssed by a Pire Departmcnt Inspeclor. Call (425) 257-812G to make an appointment for <br /> inspcction. Contractors' malcrials and tesl certificates shall be sub_nitted to the Everett Fire <br /> llcpartment prior to issuance of any Certi6cates of Occupancy. Call (425) 257-8124 for motc <br /> information. <br /> 11. Thc location ot' Fire Uepartment connections (FDC) and post indicator valves (PIV) shall be <br /> determincd by thc Fire Code OfficiaL If immediate outsidc mand�or access is available to the <br /> sprinkler valves (riscrs), a YIV will not bc required. Locate thc 1'1" and FUC on the NL corner of <br /> the building. <br /> s <br /> �1� <br />