Laserfiche WebLink
' � � <br /> 2. A Knox Box is required. <br /> 3. Fire Lane Markin¢, - Fire apparatus access roads shall be mazked whenever necessary to maintain <br /> the unobstructed minimum required width of roadways. Fire lanes shall be marked as follows: <br /> a. Curbs shall be identified by red traffic paint with a 6-inch wide stripe on the top and front, <br /> extending the length of the designated firc lane. <br /> b. Rolled curbs shall be identified by red traffic paint with a 6-inch wide stripe on the curb, <br /> extending d�e lengtl� of the designated fire lanc. <br /> c. Lanes without curbs shaU be identified by red traffic paint with a 6-inch wide stripe on the <br /> pavement, cxtending tlie lengt6 of thc designated fire lane. <br /> d. Thc wotds 'NO YARKING - FIRL LANE' shall be in 3-inch strokc white Ietters 18 inches in <br /> height, and placcd 8 inches measurcd perpendicular from the red paint stripe on the pavement. In <br /> most cascs, both sides of the access road shall be marked. Where long drives arc to bc marked, the <br /> repetitions shall alternate sides of the drive. <br /> e. Marking shall also indude the addition of inetal signs stating 'NO PARKING - FIRE LANE- <br /> TOW AWAY ZONC' to bc installed at intervals or locations designated by the Firc Code Official. <br /> 'The signs shail be approximatcly 12 inches in width and 18 inches in height and have red letters un <br /> a white background. Metal signs shall be installcd on either 2-incti metal pipes for private propetty <br /> or treated 4-inch by 4-incl� wood posts for public property and shall be located so that the bottom of <br /> the sign is a minimum of 7 fect abo��c the curb. Where Cire lanes are adjacent to buildings or <br /> structures and whcn approved or directed by lhe Fire Code O(ficiai, the signs may be placed on the <br /> face of Q�e building or structure. <br /> f. Where dircctcd by the Fire Codc Official, spccific areas shall bc designated and those areas are <br /> to be marked with diagonal striping across thc width of t6e fire lane. Diagonal marking shall be <br /> used in conjunction ���ith painted curbs and/or eclge striping and shall run at an angle of 30 to 60 <br /> dcgrees from one side to the othcr. These diagonal lincs shali bc in red traffic paint, parallel with <br /> caeh other, at least 6 inches in width and 24 inchcs apart. Lcttcring shall appear as above. <br /> 4. Firc tlow for this project is 1,500 gpm. <br /> 5. Portablc Firc Protection - A portable fire extinguisher with a minimum U.L. rating of 2-A:10- <br /> 13:C shall be provided within 75 feet of travcl on all floors of each building during construction and <br /> prior to occupancy. <br /> 6. Gara es - Install a portable fire cxtinguislier with a minimum U.L. rating of 2-A:40-B:C within <br /> 30 fcct travd dislance of all portious of this building. <br /> 7. Fire�drants - Locations as planned are acceplable. <br /> 8. Vremise Idcntification - Premises shall be dearly identified by the correct address at the street <br /> entry. I3uildings shall be cicarly identificd so as to be visible and legible from the access road. <br /> Individual ap•r.rtmenis and suitcs, wlicrc applicable, shall be clearly and legibly identified from the <br /> access road. Use 8" numbers on the building, 4" numbers on suites. <br /> a <br /> Y�� <br />