� 1216-4d <br /> • i <br /> 6. Where changes of elevation of less than 12 inches should be shown on the drawings. IBC <br /> section 1017.2 <br /> Changes in elevation are indicated on sheet A0.2. <br /> 7. Tactile exit signs should be shown on the drawings adjacent to each door to the exit <br /> discharge. IBC section 1011.3 <br /> Tactile exit sign locations are indicated on revised sheet A2.l. <br /> 8. Exii discharge cannot reenter the building. 16� section 1027.1 <br /> Exit discharge does not reenter the building. The exit through the parking garage <br /> discharges directly to the public way. Refer to revised sheet A0.2. <br /> Construction <br /> i <br /> �1. Please indicate on the drawings that the minimum STC and IIC ratings have been met by <br /> existing construction or a combination of existing and new construction to separate the residences <br /> above from the tenant space. IBC section 1207.2 and 1207.3. <br /> The STC rating for the existing floodceiling stru�ture construction (11.25" thick <br /> concrete slab) separating the tenant space frort� the residences a6ove is 60, which meets the <br /> requirement of not less than 50. The IIC rating does not apply to the commercial tenant <br /> space sirce it is only applicable when the residential space is below. <br /> ✓2. Hardware for new doors should be identified on the door schedule to not require tight <br /> grasping, pinching or twisting of the wrist to operate. IBC Section 1008.9.1 <br /> This information is listed on the door schedule general note A sheet A9.1. <br /> Accessibilit <br /> 1. Please show the following dimensions in all toilet rooms: ICC A117.1-2003 Section 603 <br /> a. Toilet paper dispenser distance from toilet <br /> b. Clear turnaround space (not impaired by fixtures) <br /> c. Five foot clear space at toilet (between wall and sink) <br /> Dimensions/clearances have been added to drawings. Refer to revised sheet A2.1 and <br /> sheets A7.1 and A7.2. <br /> Ener <br /> 1. Steel stud walls should be shown with minimum R-13 plus R-7.5 continuous insulation at <br /> exterior walls, or walls adjacent to unheated or semi-heated spaces, such as the adjacent garage <br /> and adjacent unoccupied tenant space. WSEC table 13-1 <br /> Wall details have been revised to indicate the appropriate insulation. Refer to revised <br /> sheet A6.1. <br /> I'a�;r 3 uf�t <br />