My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1303 PACIFIC AVE 2016-01-01 MF Import
>
Address Records
>
PACIFIC AVE
>
1303
>
1303 PACIFIC AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2017 5:27:27 AM
Creation date
2/25/2017 5:27:17 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
1303
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. i 1216-4d <br /> Detection/Alarm System. Scope of work includes extension and installation o/these systems <br /> into tenant space. Refer to revised sheet A0.1. <br /> 2. No comment listed <br /> 3. Separated use of occupancies requires a fire-resistance rating between the Everett Clinic and <br /> the garage, in addition to the tenant demising wall. Please indicate tested assemblies and <br /> penetrations on the drawings, or indicate limits of occ�pancy types for the adjacent tenant suite. <br /> IBC table 508.4 <br /> The building meets the requirement for Non-Separated Occupancies per IBC 508.3 and <br /> 509.2 Horizontal�luilding Separation Allowance. No �re resistance rating is required <br /> between tenant spase and parking garage or between tenant spaces on ground floor. <br /> � • <br /> 1. The exit travel distance shown on the drawings exceeds the common path of egress travel, <br /> which requires two exits from the tenant suite. IBC section 1014.3 and 1015.1(2). <br /> Door 117A has been designated as a second exit. Refer to revised sheets A0.1, A0.2 <br /> and A3.1. <br /> ✓� 2. Illuminated exit signs should be shown on the drawings to two separate exits. If egress is <br /> required through the intervening space of the garage, exit signs should be shown on the reflected <br /> ceiling plan of the garage to provide a discernible path of eyress. IBC sections 1011.1 and 1014.1 <br /> Refer to revised sheets A0.l, A0.2 and A3.1 for location of exit signs. Exit related <br /> information for the parking garage can be found on sheet A0.2. <br /> � 3. Emergency lighting should be shown on the reflected ceiling plan of the garage, if this is the <br /> path of egress for the second required exit. IBC sections 1006.1 and 1006.3. <br /> Refer to revised sheet A0.1, A0.2 and A3.1 for exit and emergency lighting information. <br /> Exit and emergency information for the parking garage can be found on sheet A0.2. <br /> �` 4. if the garage entrance is locked, access to an unlocked man door within the garage <br /> directly to the public way should be provided. IBC section 1014.2 (2) <br /> The opening at the west end of the parking garage has no door and provides direct <br /> access to the pubJic way. There is an exit dooi at the eost end of the building, accessed from <br /> the parking garage via a corridor that allows direct access to the public way. <br /> "5. Clear aisle width of minimum 36 inches should be shown on the drawings. IBC section <br /> 1017.2 <br /> The width of all aisles and corridors is indicated on plans, refei to revised sheets A0.2 <br /> and A2.1. <br /> I',,�;,, , „i i <br />
The URL can be used to link to this page
Your browser does not support the video tag.