Laserfiche WebLink
required. Landscaping must be provided per Sectien 35.OSOE <br /> of the Zoninq Code. Calculations of interior parkinq lot <br /> landscapinq must be provided at the time of buildinq permit <br /> application. <br /> c. A minimum of ten feet of landscapinq must be provided along <br /> the property's frontaqe on Fulton Street. This area must be <br /> landscaped to Type iiI standards. <br /> d. Landscapinq must be provided in accordance with condition �4 <br /> under, Mitiaation of Adverse Imoa s by SEPA of this MDNS. <br /> e. Prior to issuance of any permits, landscapinq plans must be <br /> reviewed and approved by the Planninq Department per Section <br /> 35.100 of the Zoninq Code. The landscapinq plan must show <br /> location and dimensions of required veqetated swales, <br /> wetponds, detention ponds, rockeries and retaininq walls, <br /> and qrading at 2 foot intervals. Irrigation systems must be <br /> provided in all landscaped areae per Section 35.130 of the <br /> 2oninq Code. A 2 year maintenance assurance device must be <br /> provided for the landsaapinq per Section 35.13oB of the <br /> Zoninq Code. <br /> 24. Based upon 138,000 square Eeet of Type V-N, sprinklered <br /> construction, the fire flow rev,uirement is 4,00o GPN. <br /> 25. a fire flow requirement of 4,000 GPM requires that 4 fire <br /> hydrants be provided within 200 drivinq feet of the buildinq. <br /> 26. Vehicle acc�ss for firefiqhtinq equipsent appears adequate, based <br /> on the site plan dated Auqust 28, 1992. Access requirements for <br /> firefiqhtinq personnel into the buildinq may vary dependinq upon <br /> any high piled combustible storaqe applications. <br /> 27. A sprinkler systes complyinq with UBC Standerd 38-1 and/or NFPA <br /> Standard 13 aust ba provided. <br /> Plans for any such system must be submitted to the Buildinq <br /> Department and th� 8v�ratt Fire Department for examination and <br /> npproval. Such plans suat include plans for the underqround <br /> mains that will supply the sprinkler system. <br /> As of Janusry, 1991, sptinkler system permits are issu�d by the <br /> Buildinq D�partaent. Plan review fees are assessed by the <br /> Buildinq D�part�ent. No fee ia asseesed by the Fire Depert'ent. <br /> Above qround sprinklar pipinq must be hydroetatically tested as <br /> eetablish�d in NFPA standard 13. Undarqround piping muet be <br /> hydrostnticelly taat�d and flushed as establiahed in NFPS <br /> Standard 24 !or privat� fire mains. All such tests must be <br /> witnessed by a Fire Depertsent inspector. Call 259-8710 ta make <br /> an appoint�nt for inspection. <br /> 8 <br />