Laserfiche WebLink
'• liugh Warrc��l��Z�(�f�,� D� <br /> � �E. /�-2-7 T �-{F�'�i � <br /> ,o^+ erry Carroll �r�� ,� / c� c�� <br /> �><< c'°`` "� <br /> .rc 12-2-77 t � ��ya,..LN�.� (.x��.,� <br /> ��r-�_S d N �'L3�rr,:v=J �J�.J t'[I•��7 . <br /> ,B,«rDenny'e Restaurant ° r� / <br /> ��TY O� CVERfTf. �yEk�TT, W�SNINGTOM . <br /> We have reviewed the plans for subject development. Following are our commente <br /> relative to the construction diviaion's area of responsibility. <br /> 1) Alley should be regraded with the low point in the middle af alley to bring <br /> all eurface water to a catch basin and into the 48" eanitary interception. <br /> Z) Reeurface alley with 2" aephalt minimum <br /> ,1 <br /> 3) An addition catch baein ehould be added to the parking lot area, (Suggestion <br /> only. This ie on private property and is owners area of concern. ) <br /> 4) I believe Craig Thompeon hae epecific recommendation on how etorm water ehould <br /> be routed into the interceptionrnn:«. <br /> 5) If treee are to remain on Pine Street, ramp nea• eidewalk up a eufficient distance <br /> to eliminatc problem with roots. <br /> . 6) Remove exis tin� curb from point of curvature on Pine Street, around the corner <br /> and eaet on Pacific to Maple. A type E-1 cement concrete curb ehould be re- <br /> conetructed in its place. ' <br /> 7) All new sidewalk ehould be "Type B" (APWA Specification) <br /> � B) New driveway approachca should be "Cemer.t Concrete Driveway Type B or <br /> � Type A" ae required, <br /> 9) Catck $aeins should be Type I-C (APWA Specifications) � . <br /> 10) A whee] chair ramp should be conetructed at the corner of Pine and Pacific. <br /> 11) Install Type 60B traps in all catch basins. <br />