My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
900 PACIFIC AVE BREAST CENTER 1ST FLOOR 2018-01-02 MF Import
>
Address Records
>
PACIFIC AVE
>
900
>
1ST FLOOR
>
900 PACIFIC AVE BREAST CENTER 1ST FLOOR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2025 9:14:43 AM
Creation date
2/25/2017 8:14:49 AM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
900
Unit
BREAST CENTER
Tenant Name
1ST FLOOR
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8 . � <br /> � � � � <br /> F 14 � Sprinkler system working plans shall be subroitted for approval before any <br /> • equipment is installed or remodeled. Deviation fro4n approvcd plans will requus <br /> pamission. Working plans s6a11 contain all data as indicated in Section 1-9.2, <br /> Unifo�m Building Code Standard No. 38-1. Pla"�9^d soecific�ons.incl�din¢ <br /> �rrirn���IC CLCIlI�O:.S.Ch8!a^D III:AIIIDIitN��^_.^.^!�rA*"�bv a Washin¢ton <br /> Stat�L.ficens�Fire Se�ntier C�nhactor,w�be rUu_me�without eeview. Plans <br /> and specifications may be submitted separately from constn►ctia►docume"ts <br /> during tha conswction of the projcct.For small renovation projects in which heads <br /> are only to be relocated,a plan that shows the relocadon of devices can be <br /> submitted for review in lieu of the above requiromsnts. Sx. IOGl.3,Uniform Firo <br /> Code <br /> Noted in response received 3/5/2002 that plans will be submitted sepazately. <br /> Accepted S/19/2002. <br /> 14.1 Not Approved 4/23/02 Provide and show hangers on all atmovers greater than 24 <br /> inches in length. Sec. 6-23.4,NFPA 13 <br /> Accepted 5/17/2002. <br /> F 15 � Complete plans and specifications for the fire alarm system installation or <br /> � modification shall be submitted for review and approval prior to system <br /> installadon. Plans and specifications shall include, but not be limited to,a tloor <br /> plan; location of all alartn-initiating and alartn-signaling devias:alartn-control and <br /> trouble-signaling equipment; annunciation;power connectior.;battery calculations; <br /> conductor type and sius; voltage drop calculations;name,addross,and phone <br /> numbet of the agency receiving off-premises cransmission of alazm;and the <br /> manufacturer, model numbers and lisdng informadon for all eyuipment,devices, <br /> and materials. incorr►gle�"nla�s��d�necifica��ons will be;eturned without review. <br /> Plans and specifications may be submitted separacely from construction documents <br /> during the conswction of the projxt.For small rcnovation projects in which <br /> devices are only to be relocated,a plan that shows the rclocation of dcvias can be <br /> submitted for review in lieu of the above rcquirements. Sx. 1001.3,Uniform Fire <br /> Code <br /> Noted in response received 3!6/2002 that plans will be submitted sepazately. <br /> Accepted 5/2?J2002 <br /> l?' <br /> Page 5 of 8 Plan Review Comtnents for Ptoject N 6433 <br /> Review Key: A=Architcct F=Firc 8c I.ik Safdy 5=Sanitri�n M=MxhmfcY/Blecttial C.Coafamoe No1e <br />
The URL can be used to link to this page
Your browser does not support the video tag.