Laserfiche WebLink
� r C�� <br /> PUBuc wQR�rs <br /> June 8, 2011 <br /> Alfred I Jubie <br /> 1821 19`h Dr <br /> Mukilteo, WA 98275 <br /> Subject: Project: ]ubie <br /> Job Address: 3213 Oakes Ave A, B & C, D <br /> Plan Check No: C1105-020 &C1105-021 <br /> Dear Mr. Liger: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons Ifsted below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2009 International Building Code,) (2009 Intemational Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2009 Edition, and adopted by the <br /> City of Everett, unless stated othenvise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Buiiding Division with two new complete sets of drawings reflecting the <br /> corrections requested. <br /> 1. S��ortinc�Construction: When Floor assemblies are required to be fire-resistance rated <br /> by Section R302.3, the supporting construction of such assemblies shall have an equal <br /> or greater fire-resistance rating. Show details(s) of vertical assembly and show location <br /> on Floor plan. <br /> 2. Provid� details and specifications for 1-hour fire-resisting floor/cefling assembly. Show all <br /> components; provide specific reference to tested assembly. <br /> 3. Update energy code reference to 2009 WA State Energy Code (WSEC), R-Values, V- <br /> Values and option # shown are from 2006 WSEC (cover sheet). <br /> 4. Supply and return duchvork in unconditioned spaces shall be insulated to min. R-8. <br /> 5. Specify whole house fan to be 1 Sone on plans. <br /> 6. For Ventilated Foundations, one ventilating opening shall be located within 3'-0" of each <br /> corner of the building, except one side of the building shall be permitted to have no <br /> ventilation openings. <br /> 5/kcdliwNlieilmaNC1�05�0070 6 CI I05-02i(7213 Oakes Ave A,B 6 C,D) <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax {425) 257-8882 'I�j <br />