Laserfiche WebLink
� Vapeldl � � � <br /> C�I05-010 6 CI705-021(7217 OaklS Ave A,e!C,0) <br /> w�e e,mu <br /> 7. Stub-out #4 rebar at 18" O.C. at concrete porch to resist differential setting. 7 �/a" max <br /> rise at step-down to porch. <br /> 8. The foundation ventilation shown under the ABWP'S conflicts with the required anchor <br /> bolts please clarify, <br /> 9. Alternate braced wall panels (ABWP) are limited to use on the first floor of one and 2- <br /> story structures. Revise braced wall designadans to comply presc�iptively or provide <br /> �ateral analysis prepared by a licensed WA SWte Structural Engineer. <br /> 10. All common areas are required to be separated from both units with one-hour fire- <br /> resistive assembly. The common entrance, mechanical rooms and storage rooms (at first <br /> floor) are required to be separated from both units. <br /> 11. Please be advised that all corredions are applicable to both buildings. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your applicatlon will be glven priority and plan revlew will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient informatlon to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> � �.��.�- <br /> ]eff Hei man <br /> Development Technician <br /> 425-257-8976 <br /> Email: iheilman@ci.everett.wa.us <br /> s/kcaiisoNneunaNU lO5�o20 6 Cuos-011 p2U Oakes�w A,e s 40) \� <br />