Laserfiche WebLink
. �; ( �� <br /> EN6/NEE/P1N6/P!/OUC SrERY/CE5 OEPARTAIENT <br /> ,,. <br /> October 3, 2008 <br /> Chong Yi <br /> 10120 Meridian Ave <br /> Everett WA 98204 <br /> Subject: Project: Chong Yi <br /> Job Address: 10124 Meridian Ave <br /> Plan Check No: BO <br /> Dear Mr. Yi: ��g ��� <br /> In response to your application for a construction permit, your plans have been examined and you are advised <br /> that die issuance of a permit is being withheld for the reasons ]isted below. These commenls addtess building <br /> issues only. Additional revisions or additions may be required by other departments (such as Utilities, Planning <br /> or Fire). All references refer to lhe (20(K Intemational Building Code,) (2006 International Residential Code,) <br /> as amended by the State of Washington and/or Washington State Energy Code 2006 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to provide t6e Building <br /> Division with two compiete new sets of drawings retlecting the correctioas requested. <br /> p v 1. All exterior walls shall be braced in accordance with section R602.10. In addition, interior <br /> braced wall lines shall be provided in accordance with Section R602.10.1.1. For buildings in <br /> Seismic Design Categories D0, D1 and D2, walls shall be constructed in accordance with the <br /> additional requirements of Sections R602.10.9, R602.10.11, and R602.11. <br /> o �/2. Ducts shall terminate outside of the building minimum 10'-0" from any opening into the <br /> building or 3'-0" above any opening into the building. <br /> ° � 3. Provide 2 x 6 framed wall with R-21 insulation between the garage and the house. Show the <br /> requirement on the plans. <br /> � � 4. Provide minimum 36" landing at the bottom of the stairs, at least as wide as the stairs. Show <br /> thc rcquircment on thc plans. <br /> ° �5. Provide minimum R-30 insulation under the stairs in the garage. Show the requirement on <br /> the plans. <br /> �, v 6. The intermediate balusters on guards shall be spaced such that a sphere 4 inches in diameter <br /> cannot pass through any opening in the guard. A 4 inch space would allow the passage of a 4 <br /> inch sphere. Please revise the specification shown on the plans. <br /> ° 7. Update code references to the currently adopted codes, specifically the 2006 International <br /> v Residential Code (IRC), 2006 WA State Energy Code (WSEC), and the 2006 WA State <br /> Ventilation and Indoor Air Quality Code (WSVIAQC). <br /> � j/8. Provide 3" x 3" x 1/4" plate washer on all anchor bolts in braced wall lines. Show the <br /> requirement on the plans. <br /> RtdlivJll�ilmx'M809{U2IIOIN Meridi�n A�el <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 <br />