<br /> ' C6MPLIANCE NWEC LOWRISE RESIDEN"IAL COMP�IANCE CHECKLIST
<br /> Reou�eeo F"' Electrically heated dwellings, s 3 stories, 2one 1, Wesiern Washington .;
<br /> ' � �-:.. � � - .���; ��: : ��� . � .�.;�d ,:,�� . �� ,,� M„ . � u%;u�
<br /> , ,,< ,_
<br /> � INSPECTION
<br /> APPROVtD IMPORTANT: Please supply Iniormatlon requesleC �n ihe approprlate
<br /> shaded boxes below. Disrepard boxes that don't descri:� �nur buildinp or
<br /> equlpment. Q.O�LQ.Iplace checks In the two left columns.
<br /> INSULATION PHASE
<br /> , . .,-,,, ,. .,...
<br /> Is!�ncluding rim joists) will be insulated without compression to: �n�'
<br /> [� R-19 batt (ChM6, options I,III,IVj ❑ R-24 (Ch #6,Option II) � R-�(Ch#4 or 5)
<br /> low grede walls not insuiated on the exterior(See FOUNDP.TIGN PHASE) will be insulated to:
<br /> Cl R-19(Chapter �, all Opticns) on the interior ❑ R•_(Chapters 4,5, or 7)on the interior.
<br /> aulted cellinps will be insulated without compressbn to:
<br /> ❑ R39(Ch#6, all options) ❑ R_(Ch#4 or 5)
<br /> i. ..:;,�o g ...q'^'�'�S�T'7 cn:<n.n . : .: r i T tr ,�. .:r,.^ ,�/:/.. � '. ../i.. ..c. sv.a. ......«...;
<br /> yllpht wall Insuletlon is installed anC equivalent to ihe required wall R-values
<br /> (Hecommendation:place ceiling Insuiation batts in place behind skylight wells)
<br /> -^— <,...,,^�.-�,- . .. .
<br /> apor retarders will be installed toward the warm surtace as represented below:
<br /> Select one o���li999���for floors,walls, and appropriate ceilings:
<br /> Floors: �Plywood Iabeied EXPOSURE 1 ❑ Poly (a 4 Mil) ❑ backed batts ❑ PVA
<br /> Walls: Poly plasUc (z 4 Mil) ❑ backed batts �PVA
<br /> Ceilings: ❑Not required where ventilation space averages >12" above insuiation.
<br /> ❑Pdy plasttc ( 4 Mtl) ❑ backed betts VA
<br /> Haetinp �ystam efflcl�ncy and sizinp requirements will be met as represerned below:
<br /> Maxlmum heating system capacity (150%oi design heat load) has been calculated at��KW
<br /> Heat Pump efticlency will be met underthe(ollowing compliance path:
<br /> ❑Ch#6, Option IV: air source heat pump: HSPF 2.6.8
<br /> ❑Ch#5 air source heat pump: HSPF z 6.8, COP 2 2.7/2.0
<br /> O Ch q5 water�ource heat pump:COPZ 3.0
<br /> �uct►ng system requlrements wl!1 Is met with tollowinp system:
<br /> Mfr. Model N Maz. output KW �
<br /> Type HSPF COP
<br /> >
<br /> �; , . . . .. , ..,,.,.. �,----->--_-.,.:..�--^-_,,,, . . _ . . . '
<br /> NWEC Insulatlon pa�a�r4�uirements:
<br /> Approved by: o � �� t
<br /> Date `
<br /> WEE911PNILiO Page 6 oi 7