Laserfiche WebLink
1 � <br /> Ll.NCE MUELLER 6 ASSOCIATES <br /> � 4 N C M t T ( L T 5 • A t A <br /> Decer,iber 8, 1997 <br /> � ���� M <br /> Mr. Tim Tyler O� L% � <br /> Mr. Steve Miller (� Q� n <br /> Mr. Tony Lee ' �J (f <br /> _..�.._...... <br /> CITY OF EVERETT BUILDING DEPARTMENT A��'��t� <br /> 3200 Cedar Street �R(� ���' <br /> Everett, Washington 98201 �hiy"'�� <br /> Re: PROPOSED SOLECTRON MANUFACTURING FACILITY <br /> LO7 2F, SEAWAY CENTER <br /> LMA JOB#97-138 � n�,�.M�� (35 7SL y <br /> Gentlemen: <br /> As discussed at our meeting on November 25, 1997, we request that mitigating <br /> circumstances eliminate the necessity for praviding one-hour rated corridors at the common <br /> area of the Solectron facility. Additionally we would like to demonstrate the exiting for the <br /> cafeteria prior to application for the tenant improvement in order to expedite review time once <br /> the plans are submitted. <br /> Please see the attached exhibit that deiails the above mentioned areas of the facility. <br /> The following comments pertain to the design intent of the exiting system: <br /> 1. Due to the potential occupant load for the common area, I have placed a two-hour <br /> horizontal exit wall around th� perimeter of the conference and training area. This wall <br /> essentially creates a separate building when leaving the common area hallway and <br /> entering into the building link to the individual wings of the building. <br /> Z. The majority of rooms located within the common area are meeting/conference rooms <br /> for Solectron employees and limited guests to the facility. Seating in the rooms and <br /> lobhy area will accommodate approximately 103 persons while the occupant load <br /> shown is 212 persons. ' <br /> 3. Exits to the exterior or through the two hour horizontal exit are within fifty feet of any <br /> room and clearly visible to the occupants that would meet in any room. Proposed exit <br /> signs are shown. <br /> 4. I have listed the occupant load for each room at the door and totaled the occupant <br /> load at doors exiting to the e�Rerior to demonstrate compliance with the code. When <br /> exiting through an adjoining room or space the occupant load shown at the exit <br /> includes the occupant load portion for room or area of said occupants. <br /> t�0 L4KESIOE • SUITE 2�J0 • SEATTLE. WA • 90'122 • (206) 3P6•2663 • FAX; f20B1 32B•0564 <br /> ` AqCNITECTURE • PLANNING • SPACE PLANNING • INTERIORS <br /> 1 <br />