Laserfiche WebLink
_ � <br /> PUBL/C /�t/Ol�K.S' <br /> M <br /> January 14, 1998 <br /> Mike Warren <br /> Quadrant <br /> PO Box 130 <br /> Bellewe, WA 98009 <br /> Subject: Owner: Solectron Washington, Inc. <br /> Job Address: 6300 Menill Creek Parkway <br /> Plan Check No.: B 57524 <br /> Dear Mr. Warren: <br /> In response to your application for a construction permit, your plans have been examined and you are <br /> advised that the issuance of a permit is being withheld for the reasons listed below. These comments <br /> address building issues only, additional revisions or additions may be required by other departments <br /> (such as Utilities, Planning or Fire). All references refer to the 1994 Unifortn Building Code, as <br /> amended by the State of Washington and/or Washington State Energy Code 1995 Edition, unless <br /> stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division w�th two complete new sets of drawings reflecting the <br /> corrections requested. <br /> Occupancy <br /> 1. Buildines housing high-piled combustiole storage must comply with Article 81, UFC. Prescribed <br /> in tha! article are the plans and specifications submittal (Section 8101.3.2) required to receive a <br /> � � - � certificate of occupancy from the fire department. For a timely review, that information should be <br /> � prepared as soon as possible. If that information v�ill not be reviewed with the Tenant <br /> Improvement documents, then they should be listed on the cover shee[ as a deferred submittal as <br /> outlined in Section 106.3.4.2. In order to complete the review of this TI submittal, die <br /> commodity classification per Section 8101.4 should be submitted to verify the requirements based <br /> on Tables 81-A and 81-B. -}� <br /> !1 _/r�;�c a�-r lL,e,, f c,. , ( <br /> 2. The chemical inventory memorandum, prepared by Mr. Rick Berg, does not specify which <br /> category (class I-A, I-B and/or I-C) the listed 3.3 Flammable liquids fall under. As the total <br /> amount of flammable liquids exceed the allowable amount for one control area (the entire <br /> building), a more exact listing will be required. Additionally, all proposed hazardous materials <br /> per Table 3-D and Tab(e 3-E should be provided as well, even if only kept in small quantities. <br /> 3. If room C15 is to be used for a conference room, however infrequently, than it should be <br /> classified as an A-3 Occupancy, doors C16 and C14 would need to be equipped with panic <br /> hard.vare (and all doors via the exit path to the exterior). Section 1016.4 <br /> CITY OF EVERETT• 320D Cedar Street • Evereti,WA 98201 •(425) 257-8800 • Fax(425) 257-8856 <br />