My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6300 MERRILL CREEK PKY BASE FILE 2018-01-01 MF Import
>
Address Records
>
MERRILL CREEK PKY
>
6300
>
BASE FILE
>
6300 MERRILL CREEK PKY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 9:59:36 AM
Creation date
2/25/2017 10:39:20 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6300
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
689
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� �" , <br /> I <br /> Plan Check No. B 57524 � <br /> January 14, 1998 � <br /> Page 2 of 3 <br /> - � - <br /> 4. If any rooms shown are to be used for educational purposes which would necessitate the use of <br /> hazardous materials for training, then those areas should be specified on the plans. Additionally, <br /> a one-hour occupancy separation would be required to separate such room(s) from each other and <br /> the rest of the building. Section 304.2.2.1 <br /> Construction <br /> �The area separation wall should continue from the foundation to the roof with no horizontal <br /> offsets. The door alcove with soffit shown dces not comply. The wall should be shown to <br /> continue vertically from the location of the doors. If a soffit is desired, the construction would <br /> only be required to be of one-hour fire resistance. A detail should be provided. Section 504.6.4, <br /> ex 2.2. <br /> '� e 2. It should be noted on the plans that smoke/fire dampers will be required for any ducts penetrating <br /> the area separation wall. Sections 713.10 & 713.11 <br /> 3�Two-hour area separation waps may terminate at the underside of noncombustible roof <br /> construction provided (per exception 3 to Section 504.6.4): <br /> a) Openings in the roof are not located within 5 feet of the wall. Cuttently, two roof drains are <br /> shown in the location of the wall on Sheet A1.4. These drains should be moved. <br /> bj The entire building is provided with nut less than a Class B roof covering - please verify. <br /> Exiting <br /> �%��. <br /> � 1. Panic hardware should be provided on exit doors C3, C4, C27 and $11, as well as C34 and C33. <br /> " In lieu of this, doors may have no locks or latches. Section 1016.4 � -}_. r � <br /> � <br /> / <br /> 2. Battery backup should be specified on the plans for the exit signs. Section 1013.4 <br /> Accessibility <br /> ii� To confirm widi General Note N7 on the cover sheet, we will not require the written fire and life <br /> safety evacuation plan to be submitted prior to the issuance of the building permit, however, it <br /> will be required ro be approved prior to the issuance of the certificate of occupancy. Sections <br /> 1104 and 106.3.4.2 <br /> � <br /> Energy <br /> i <br /> 1: The lighting is the only portion of the energy code to review under the tenant improvement : <br /> permit. The lighting has been specified as a desigNbuild on the cover sheet and will be submitted � <br /> under a separate permit. <br />
The URL can be used to link to this page
Your browser does not support the video tag.