My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6300 MERRILL CREEK PKY BASE FILE 2018-01-01 MF Import
>
Address Records
>
MERRILL CREEK PKY
>
6300
>
BASE FILE
>
6300 MERRILL CREEK PKY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2018 9:59:36 AM
Creation date
2/25/2017 10:39:20 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6300
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
689
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C � <br /> February 3, 1998 <br /> Mr. Tony Lee <br /> Associate Engineer <br /> CITY OF EVERETT <br /> Page Two <br /> e. Curtain boards will be located as shown on the plans. The specific areas <br /> designated as high-pile are surrounded by curtain boards with the area not <br /> to exceed 10,000 s.f. per Article 81. The remainder of the building will <br /> have curtain boards with the area not to exceed 50,000 s.f. <br /> f. Small hose stations will be provided in the high-pile storage areas and will <br /> be located whe� m(re information is known about rack layout. <br /> �C� ,,'�'4�IM�FjS <br /> � 2. The Owner wdl provide the list as requested. The design intent of the building will <br /> ..�' be that overall, the hazardous materials within the building will not exceed the <br /> exempt amounts listed in U.B.C. Table 3-D or 3-E and ali materials will be kept in <br /> approved fire/storage cabinets. <br /> � Room C-15 will not be used as a conference room. <br /> � The Owner has stated that small spill-proof containers containing a solution of <br /> i 70% isopropyl alcohol/30°h water and flux pens will be the only items used in the <br /> room that could be construed as potentially hazardous. Due to the nature of <br /> these items, we request that one hour separation not be re uired. � <br /> CONSTRUCTION <br /> /1' The i�orizontal exit will run from the floor to underside of roof decking and the <br /> offset has been eliminated. <br /> ,�/1�^ A note stating: "Smoke/fire dampers will be required for all ducts penetrating the <br /> horizontal exit wall"will be added to the enlarged plan on sheet A2.2. <br /> f <br /> �=3. The horizontal exit will run from the floor to underside of roof decking. <br /> �a�. N/A <br /> �. The entire building will have a Class "A" roof covering as noted on the wall <br /> sections. <br /> � �XITING <br /> �''�- -� +�� The doors noted will have panic hardware. <br /> ,Z. Battery backup is noted on exit lighting on sheet A6.1 and the floor plans. <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.