. . � � <br /> , ^ <br /> �-. <br /> The Quadrant Corporation JN 95292 <br /> September 28, 1995 Page 3 <br /> mine if different footing widths or embedment depths are required. Footing subgrades must <br /> be cleaned of loose or disturbed soil prior to pouring concrete. Depending upon site and <br /> equipment constraints,this may require removing the disturbed soil by hand. <br /> An allowable bearing pressure of 3,000 pounds per squaze (ps� is appropriate for footings <br /> constructed a rding to the above recommendations. A one-third increase in this design <br /> bearing pr� may be used when considering short-term wind or seismic loads. For the <br /> above dc � iteria, it is anticipated that the total post-construction settlement of footings <br /> founded � � mpetent, native soils, or on structural fill, will be about one-half inch, with <br /> differentia lements on the order of one-half inch in a distance of 100 teet along a <br /> continuous tooting. <br /> Lateral loads due to wind or seismic forces may be resisted by friction between the founda- <br /> tion and the bearing soil, or by passive earth pressure acting on the vertical, embedded <br /> portions of the foundation. For the latter condition, the to�indation rnust be either poured <br /> directly against relatively level, undisturbed soil, or surroun�ed by level, structural fill. We <br /> recommend using the following design values for the foundation's resistance to lateral <br /> ' loading: <br /> Parameter __ esign Val�p <br /> Coefficient of Friction 0.45 <br /> Passive Earth Pressure 350 pcf <br /> Where: <br /> (1) pcf is pounds per cubic foot. . <br /> (2) Passive earth pressure is computed using the <br /> equivalent fluid density. <br /> If the ground in front of the foundation is loose or sloping, the passive earth pressure given <br /> above will not be appropriate. We recommend a safety factor of at least 1.5 for the <br /> foundation's resistance to lateral loading, when using the above design values. <br /> Seismic Considerations <br /> The site is located within Seismic Zone 3 as illustrated on Figure No. 23-2 of the 1991 <br /> Uniform Building Code (UBC). In accordance with Table 23-J of the 1991 UBC, the site soil <br /> profile is best represented by Profile Type S2. <br /> GHOltiC1I CONSUI;li\NIS,ING <br />