Laserfiche WebLink
PROJECT NAME: NASSAU <br />PAGEdq OF <br />PROJECT No.: 2122 DATE: 08/11/02 <br />SHEARWALL TABLE <br />TYPICAL SHEARWALL NnTES <br />1) USE Sd COOLER NAILS FOR 7/Z" GWB <br />USE 8d COOLER NAILS FOR 5/8" GWB <br />2) ALL NAILING IS PER U.B.C. TABLE 25-I OR 23-II-B-1 <br />3) 1/2' DIAMETER CINCH ANCHORS WITH 3-1/2' MINIMUM <br />EMBEDMENT MAY BE USED IN LIEU OF t/2" OIAMETER <br />ANCHOR BOLTS <br />4) USE 2x2�c3/18" SQUARE PLATE WASHERS FOR ALL <br />ANCHOR BOLTS PER UBC 1806.8.1(2) <br />5) 1-1/4" TYPE W aM8 BUGLE HEAD SCREWS MAY BE USED <br />FOR 1/2' G1N6 IN PLACE OF Sd COOLER NAILS <br />SHEAR WALLS <br />CAP AAARK CALLOUT <br />2P0 Typical USE 1/2" GWB BOTH SIDES, UNBLOCKED, WITH TYPICAL <br />Interior NAILS AT 7" o.c. , 1/2" ANCHOR BOLTS AT 48' o.c., 18d PIATE <br />TO PLATE NAILING AT S' o.c., AND SIMPSON A35 CLIPS AT 18" <br />o.c. <br />213 Typical USE 1/2" APA RATED SHEATHING, BLOCKED AT PANEL <br />Exterior EDGES, WITH 8d NAILS AT 8" o.c. AT PANEL EDGES AND 12" <br />o.c. AT FIELD, 1/2" ANCHOR BOITS AT 48" o.c., 18d PLATE TO <br />PLATE NAILING AT 6" o.c., AND SIMPSON A35 CLIPS AT 18" o.c. <br />312 1Q USE 1/2" APA RATED SHEATHING, BLOCKED AT PANEL <br />EDGES, WITH Sd NAILS AT 4" o.c. AT PANEL EDGES AND 12" <br />o.c. AT FIELD, 1/2" ANCHOR BOLTS AT 32" o.c., 18d PLATE TO <br />PLATE NAILING AT 4" o.c., AND SIMPSON A35 CLIPS AT 1Y o.c. <br />412 2Q USE 1/2" APA RATED SHEATHING, BLOCKED AT PANEL <br />EDGES, WITH 8d NAILS AT 3' o.c. INTO 3� FRAMING <br />MEMBERS AT PANEL EDGES AND 12" o.c. AT FIELD, 1/2" <br />ANCHOR BOLTS AT 24" o.c., 18d PLA'fE TO PLATE NAILING AT <br />4' o.c., AND SIMPSON A35 CLIPS AT 8" o.c. <br />