Laserfiche WebLink
AUG-31-2004 12:56 <br />ANKLE 8 FOOT CLINIC <br />4252586933 <br />P.06/09 <br />23. Fire Alarm System - An approved automatic fire detection system shall be provided as required by City <br />Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. Plans for such system shall <br />be submitted to the Fire Marshal for review and approval prior to installation. Submittal shall include <br />cut sheets of all equipment intended for use. Appropriate trip tests. witnessed by a Fire Department <br />inspector, shall be performed, along with a certificate of completion, prior to final acceptance of the <br />system. Fire alarm systems shall be installed according to NFPA Standard 72. Installation of fire <br />alarm components, including basic wiring, may not commence before plans are approved by the Fire <br />Department Plan Reviewer. Fire alarm drawings must be professionally rendered, in sufficient detail, <br />and must be internally consistent. Riser diagrams must match installation plans and load calculations. <br />Components must be listed and approved for use together. Changes to plans must include new <br />drawings and calculations and must be approved by the Fire Department Plan Reviewer prior to <br />installation. Fire alarm installation is subject to field inspection by a Fire Department Inspector. An <br />approved set of plans and the Building Department electrical permit must be present for any installation <br />inspection. Fire alarm systems shall be installed under permit of the City of Everett Building <br />Department. Electrical inspections and approval are required prior to calling for acceptance tests. <br />Call (425) 257-8810 for permit information. <br />24. Fire Suppression (Sprinkler) System - An approved automatic suppression system shall be provided as <br />required by City Ordinance No. 1902-92, Chapter 16.76, of the Everett Municipal Code. The system <br />must include a mechanical water gong bell. Plans for any such system shall be submitted to the <br />Building Department for examination and approval. Such plans shall include plans for the <br />underground mains that will supply the sprinkler system. The type of sprinkler to be installed will be <br />determined by the Building Official. It may be an NFPA 13, NFPA 13R, or NFPA 13D system <br />depending upon several factors. Sprinkler installation shall not begin without an approved and stamped <br />set of plans from the Building Department, The Fire Department will also review the plans and shall <br />field inspect the installation based only on approved plans that must be on site. Changes to plants must <br />be approved by both the Building and Fire Departments. Aboveground sprinkler piping shall be <br />hydrostatically tested as established in NFPA Standard 13. Underground piping shall be <br />hydrostatically tested and Flushed as established in NFPA Standard 24 for private fire mains. Below - <br />ground mining mutit be installed by Washineton State Patrol Licensed Underground Sprinkler line <br />certified 'U installers For further information contact the State !'ire Marshal's Office at J301 <br />570 3134 or contact the Everett Fire Department at (425) 257-8123. All such tests shall be <br />witnessed by a Fire Department inspector. Call (425) 257-8123 to make an appointment for <br />inspection. Contractors' materials and test certificates shall be submitted to the Everett Fire <br />Department prior to issuance of any Certificates of Occupancy. Call (425) 257-8123 for more <br />information. <br />25. A permit is required from the Fire Department for Flammable and Compressed Gases. <br />26. All fire alarm control panels (FRCP) and sprinkler valves shall be in heated rooms or closets with <br />standard man door access. Locations shall be approved by the Fire iviarshal's Office. <br />27, Trash Collection - Garbage riumpsters over 1.5 cubic yards capacity shall be located a minimum of 5 <br />feet from the building. Garbage receptacles, dumpsters, and recycle bins shall be provided and shall <br />be located adjacent to the alley per Section 39.080 of the zoning code. The garbage dumpsters and <br />7I1) <br />s <br />