My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
18 W MCGILL AVE 2018-01-02 MF Import
>
Address Records
>
W MCGILL AVE
>
18
>
18 W MCGILL AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2022 2:56:05 PM
Creation date
2/26/2017 2:18:37 AM
Metadata
Fields
Template:
Address Document
Street Name
W MCGILL AVE
Street Number
18
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE <br />REQUIRED V <br />INSPECTION <br />APPROVED IMPORTANT: Please supply Information In the shaded boxes and check the appropriate <br />circles. Disregard topics that don't describe your building or equipment. DO NOT place <br />checks in the two left columns. <br />D ❑ © Exterior slab Insulation, it not located on the interior, shall be R-10 (Table 6-2). <br />❑ ❑ Q Exterior slab Insulation, if present, shall approved for below grade use and protected above grade. <br />❑ ❑ QWalls, including rim joists, shall be insulated without compression to (Table 6-2): <br />OR-15 batt (Options 1.11) *R-19 (Option 111, IV, V,'VI, VII) <br />❑ ❑ ®Interior below grade walls shall be insulated without compression to (Table 6.2) <br />R-15 (Options I, 11) i` 0 DR-19 (Options 111, IV, V, VI, VII) _ <br />❑ ❑ QVaulted ceilings shall be insulated without compression to R-30 (Table 6.2, All options) <br />' UM <br />MIN <br />10110 <br />Skylight wall insulation is installed and equivalent to the required wall R-values above. <br />Vapor retarders shall be installed toward the warm surface as represented below (502.1.6) <br />Select one option for floors, walls, and appropriate ceilings: <br />Floors: PlywoodW/ exterior glue 0 Poly (> 4 Mil) ,0 Backed batts <br />Walls: Poly plastic (2 4 Mil) 0 Face -stapled, backed batts ® PVA paint ' <br />Ceilings: Not required where ventilation space `averages >12" above insulation. <br />Face stapled backed batts 0 Poly plastic (r_ 4 mit) is PVA paint <br />QHeating system efficiency and sizing requirements shall be met as re res <br />® Heat Pump efficiency shall be mot underthe following compliance patp <br />0 Split system, air source I seat pump: HSPF'2 6.8 COP > 3.0 <br />0 Single package, air source heat pump: HSPF a 6.6, COP > 3.0 <br />0 Water source heat pump: COP 2 3.8 <br />0 Ground source heat pump COP a 3.0 <br />QQ Central force -air furnace AFUE rating, as listed in the LAMA Directory, shall be: <br />�2 .78 (Options I, 11,1V, VI, VII) 0 z;.88 (Option III)) 0>-24 (Option V) <br />§6! Non -central, combustion heating systems shall have intermhent ignitionMaximum heating system output (150%of design heat load) is _ BTU1hr. (S. 503High efficiency forced -air furnace (s 55,000 BTU/hr. output)may may exceed 150%of DHL <br />because: OGAMA listed AFUE IF > 78 + t per each 5000 BTUlhr output that it exoeedsthe t] , <br />pectea sulation phase re,ulrements: — <br />Inspected by: Date <br />❑ ❑ ©s Envelope Floors shall be insulated without compression, and with support s 2w O.C. to: <br />OR19 (Options 1,11, III, IV, V) 0 R25 (Options VI, Vin <br />❑ ❑ e° Non -vaulted, attic ceilings shall be Insulated without compression to; <br />4DR-30 (Options 1, 1i, III, IV, V, Vin 0 R38 (Op!lon VI) See Table 6-2 <br />❑ ❑ Q Door systems shall meet: U.40 (All options) <br />Door types are(1)gYralATr'>>r (2)_ (3) <br />Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.