November 5, 1992 <br />� <br />�U�L/C /�!/O/ZK� <br />Howazd Lorentz <br />5804 Cady Road <br />Everett, Washington 98203 <br />RE: Owner: Howard Lorentz <br />Job Address: 1033 Mukilteo Boulevard <br />Plan Check No.: 38370 <br />Dear Mr. L.orentz: <br />In response to your application for a construction permit, your plans have been examined and you aze <br />advised that the issuance of a permit is being withheld for the reasons listed below. These comments <br />address building issues only, addidonal revisions or addidons may be required by other departments <br />(such as Utilities, Planning or Fire). All references refer to the 1991 Umform Bu►Iding Code and/or <br />Washington State Energy Code unless stated othenvise. <br />�1. All exterior walls and main cross-stud partitions shall be effecdvely and thoroughly braced to <br />resist wir,d an� seismic forces per Section 2517(g)3, or provide a design and details prepared by a <br />licensed Washington State Structural Engineer equal to or exceeding the requirements of Section <br />2517(gj3, UBC. <br />J2. Show under floor ventilation opening size and locations equal to one square foot for each 150 <br />square feet of under floor area. Show the required net area calculation assuming approximately <br />75% of the vent area is net area unless the actual net azea is given from the <br />manufacturer/2516(c)5. <br />✓3. Regardless of occupant load, there shall be a floor or landing on each side of a door. A door may <br />open at a landing :!�at is not more than 8 inches lower than the floor level, provided the door does <br />not swing over the landing/3304(i). <br />1. Provide smoke detectors in ali sleeping rooms and in corridor or area giving access to each <br />separate sleeping area. Smoke detectors shall receive their primary power from the building <br />wiring and shall be equipped wi[h a battery backup, the detector shall emit a signal when the <br />batteries are low. <br />5. Plans do not show connections. Specify all post/beam, posVfooting, beam/beam connecdons. A <br />positive connection is required for uplift and lateral displacement/2516(m). <br />6. All loads are required to be supported to the foundation. The 3-1/8"x15" GLB between the living <br />room and dining room does not appear to be properly supported below. <br />7. Provide calculations for beams, cross referenced to framing/floor plans. Show all beams on <br />framing plan. <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 •(206) 259•8874 • Fax (206) 259-8883 ''- <br />