My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1033 W MUKILTEO BLVD 2016-01-01 MF Import
>
Address Records
>
W MUKILTEO BLVD
>
1033
>
1033 W MUKILTEO BLVD 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2017 6:51:22 PM
Creation date
2/26/2017 2:30:23 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
1033
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />Plan Check No.38370 <br />November 5, 1992 <br />Page Two of Three <br />� <br />�8. Specify roof slope(s) of all areas on the roof plan. Provide minimum 1/4" per foot roof slope for <br />drainage or design to support accumulated water. <br />9. Show size and location of overflow drains or overtlow scuppers/3207(c). <br />10. Provide details of attic ventilation type, size and location. Show the required net area calculations <br />assuming approximately 75% of the vent azea is net area unless the actual net azea is given from <br />the manufacturer. Enclosed rafter spaces formed where ceilings are applied directly to the <br />underside of roof rafters shall have cross ventilation for each separate space by vendlaUng <br />openings protected against the entrance of rain and snow. The net free ventilating area sf�all be <br />not less than 1/150 of the area of the space ventilated. <br />11. Provide detail of guardrail, specify all materials and dimensions, include guardrail at deck and at <br />stairs. <br />12. Occupants on floors above the second story, shall have a�cess to not less than two separate exits <br />from the floor/3303(a). <br />13. Provide tempered glass at required hazardous locadons. <br />14. Detail 2 on sheet A3 shows rigid insulation at perimeter of slab-on-grade in garage, is garage <br />heated? If garage is heated, the detail shown dces not meet energy code requirements. <br />15. Provide typical wall section, from foundadon to roof. Show and label all structural components <br />and insulation level. <br />16. Provide detail of intermediate supgorts in crawl space. � <br />17. Foundation plan dces not show footings for stairs. Design footings to support 100 pounds per <br />squaze foot on stairs. <br />18. Footings at 5-1/8"x21" GLB are not of sufficient size to support load imposed. Provide new <br />foodng size with rebar requirements indicated. <br />l9. Masonry walls are required to be insulated to minimum R-19 if insulated on the interior. 2x4 <br />fumng alone will not provide sufficient depth to install R-19 batts without compression, an air <br />space of not less than 2 inches used in conjuncdon with 2x4's will provide sufficient depth to <br />install R-19 insuladon, however the stairway along the wall would have to be shifted a <br />corresponding 2 inches. <br />20. Show all header sizes en plans. <br />2l. Total glazing area exceeds 21 % of tloor area. Prescriptive path IV may not be used. Submit new <br />compliance path or component performance calculations. Drawings shall reflect required <br />insulation levels. Submit window schedule. <br />
The URL can be used to link to this page
Your browser does not support the video tag.