Laserfiche WebLink
Preliminary Geotechnical Engineering Evaluation <br />1919 Mukilteo Boulevard <br />October 20, 2005 <br />NGA File No. 718805 <br />Page 5 <br />the specific surface soil types, which are related to the underlying geologic soil units. The Soil Survey of <br />Snohomish County Area. Washington, by the Soil Conservation Service (SCS) was reviewed to <br />determine the erosion hazard of the on -site soils. The site surface soils were classified using the SCS <br />classification system as Alderwood-Everett gravelly sandy loam, 25 to 70 percent slopes. This unit is <br />listed as having a high erosion hazard for areas where the soils are exposed. It is our opinion that the <br />erosion hazard for site soils should be low to moderate in areas where vegetation is not disturbed. <br />Landslide Hazard/Slope Stability <br />The criteria used for evaluation of landslide hazards include soil type, slope gradient, and groundwater <br />conditions. A steep north -facing slope with a gradient of up to approximately 40 degrees (84 percent) <br />with a height of approximately 100 feet is located below the planned building area. We observed <br />evidence of significant sloughing along the eastern portion of the top of the slope. Sloughing soil was <br />noted from a near vertical portion of the top of the slope near the east property line. The area of sloughed <br />soil was about 10 feet wide and exposed silty sand material. We did not observe any other scarps on the <br />slope during our site visits. We did not observe seepage or other areas of erosion on the slopes. <br />Our explorations indicate that the core of the steep slope consists primarily of medium dense to very <br />dense sand. Inclinations of up to 40 degrees on the slope indicate high strength and internal friction angle <br />within the underlying soils. Relatively shallow failures as well as surficial erosion are natural processes <br />and should be expected on these slopes. It is our opinion that while there is potential for erosion, soil <br />creep, and shallow failures within the loose surficial soils on the steep slope; there is not a significant <br />potential for deep-seated slope failure under current site conditions. Proper site grading and drainage as <br />recommended in this report should help maintain current stability conditions. <br />LABORATORY ANALYSIS <br />We performed three grain -size analyses on selected soil samples obtained from the explorations for soil <br />classification. Samples were taken from Boring I at 10.0 and 41.5 feet, and from Boring 2 at 12.5 feet. <br />The results of the sieve analyses are presented as Figures 10 through 12. <br />CONCLUSIONS AND RECOMMENDATIONS <br />General <br />It is our opinion that the planned development is feasible from a geotechnical standpoint, provided that <br />NELSON GEOTECHNICAL ASSOCIATES, INC. <br />