Laserfiche WebLink
Preliminary Geotechnical Engineering Evaluation <br />1919 Mukilteo Boulevard <br />Ij October 20, 2005 <br />NGA File No. 718805 <br />Page 10 <br />Conventional shallow spread foundations should be placed on undisturbed medium dense or better native <br />soils or be supported on structural fill extending to those soils. Where undocumented fill or less dense <br />I� soils are encountered at the planned footing elevation, the subgrade should be over -excavated to expose <br />suitable bearing soil. The over -excavation may be filled with structural fill, or the footing may be <br />extended down to the bearing native soils. If footings are supported on structural fill, the fill zone should <br />extend outside the edges of the footing a distance equal to one-half of the depth of the over -excavation <br />below the bottom of the footing. <br />Footings, including interior footings, should extend at least 18 inches below the lowest adjacent finished <br />ground surface for frost protection and bearing capacity considerations. Foundations should be designed <br />in accordance with the 2003 International Building Code (IBC). Minimum widths of 12 and 24 inches <br />should be used for continuous and isolated footings, respectively, for footings supporting one floor of <br />light -frame construction. However, footing widths should be based on the anticipated loads and <br />allowable soil bearing pressure. Water should not be allowed to accumulate in footing trenches. All <br />loose or disturbed soil should be removed from the foundation excavation prior to placing concrete. <br />For foundations constructed as outlined above, we recommend an allowable design bearing pressure of <br />not more than 2,000 pounds per square foot (psf) be used for the design of foundations supported on the <br />medium dense or better native soils or structural fill extending to the competent native soils. A <br />representative of NGA should evaluate the foundation bearing soil. We should be consulted if higher <br />bearing pressures are needed. Current IBC guidelines should be used when considering increased <br />allowable bearing pressure for short -tern transitory wind or seismic loads. Potential foundation <br />settlement using the recommended allowable bearing pressure is estimated to be less than one -inch total <br />and �h-inch differential between adjacent footings or across a distance of about 30 feet based on our <br />experience with similar projects. <br />Lateral loads may be resisted by friction on the base of the footing and passive resistance against the <br />subsurface portions of the foundation. A coefficient of friction of 0.35 may be used to calculate the base <br />friction and should be applied to the vertical dead load only. Passive resistance may be calculated as a <br />triangular equivalent fluid pressure distribution. An equivalent fluid density of 200 pounds per cubic foot <br />(pcf) should be used for passive resistance dcsiLn for a level ground surface adjacent to the footing. This <br />level surface should extend a distance equal to at least three times the footing depth. These recommended <br />values incorporate safety factors of 1.5 and 2.0 applied to the estimated ultimate values for frictional and <br />NELSON GEOTECHNICAL ASSOCIATES, INC. <br />