My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1001 E MARINE VIEW DR 2018-01-01 MF Import
>
Address Records
>
E MARINE VIEW DR
>
1001
>
1001 E MARINE VIEW DR 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/10/2018 7:51:31 AM
Creation date
2/26/2017 8:14:32 AM
Metadata
Fields
Template:
Address Document
Street Name
E MARINE VIEW DR
Street Number
1001
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� , <br /> Ltr. Moraan & Assoc. (B0406-006) <br /> July 2l, 200�1 <br /> Pa�e 4 <br /> 13)ASW #3 S 9 (same wall at this point) should continue south an additional 2=4" (depth of <br /> roof overhang) along die eastern exterior �vall of building 8 to avoid protected glazing <br /> along [he northem �vall of building 10 in an area where it wouid conflict with sleeping <br /> room cgress requirements of the units in that corner. Sections 50�3.6.3 & 310.a <br /> Id)ASVV #9 should continue north to the ed�e of the decks (of the units in building 10) for <br /> complete separation Gom building 9. Section 50=1.6.1 <br /> IS)Door #29 through ASW #9 on the 2"� level plan (into elevator equipmen[ room B1_) <br /> should be shown to be a 90-minute listed assambly. Section SOd.6.2 <br /> l6)There is an offset in the ASW #10 at the floor separating the basement and first stories. <br /> The AS�'V should continue vertically from the foundation to the roof. Section SOa.6.�} <br /> i7)ASW #I 1 shouid be shown to continuc casr or south past its current tenrin�tion al��ng ihe <br /> exterior �vali fur the depth of die rooP overLane (_'d" presurried) perpend�cular to it � <br /> behvicen buildings 9 �C 12 to provide complete separation. Section 504.6.l <br /> 1S)The note on 5heet A3.27 regarding roof openin�s within 5 fcet of AS�'4' #!3 shouid he <br /> revised to show 10` (no opening protection or AS�V necd to be conunucd aUove the Icvel <br /> of the lowcr roof in this casc). Section SOd.6.G <br /> Construction <br /> L) Por ease of revicn�, construction and inspection — the wall type le�acnd should be reprinted <br /> on each of the U3" scale Floor plan sheets and show which wall assembly from Sheet AO.� <br /> corresponds to a particular hatch type. <br /> '_) GA File No 3230 has been deleted from the GA �ianuat (17'h edition). Additionally, It <br /> was tested on only one side. The listin� on Sheet A0.�4 should bc replaced. Section 709.� <br /> 3) The 2-hour in[erior wall specifies GA File No. WP d135 and WP 3370. Neither wall <br /> description matches the proposed wall assembly as shown on Sheet A0.4. <br /> -4) We are unable to locatc GA Pi]e No B\4 113i for one-hour beam protection as shown on <br /> Sheet A0.-1 <br /> �) The typical one-hour Floor/ceiling assembly specified on Sheet AO.d refers to GA File No <br /> PC �I07. This assembly speciCies dimensional lumber. The 17'h edition of the GA <br /> �tanual now includes listings for I-joists. A more appropriate Iistin� should be provided. <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.