; <br /> Ltr. Mor�an & Assoc. (B0406-0061 <br /> July 21, 2004 <br /> Pa�e 3 <br /> Areu Separation Walls (AS�V) <br /> 1) Buildin� Sections CC/A5.3 &. JJ/A5.3 should call out the cortesponding ASN details <br /> from the 'D' series sheets. <br /> 2) The roof trusses in Detail 18/D0.1 should be noted to be a gablc-end type with vertical <br /> framing not to excecd that as specified in the wall listin�. <br /> 3) L-'xhaust vent tenninations through exterior walls should be sho�vn to be located more than <br /> 24" away from an ASW. Section 504.6.3 <br /> =t) The roof on either side of an r�SW should be shown to be of minimum one-hour Gre- <br /> resistive construction for thc depth of the roof overhang when the ASW terminates at the <br /> esteiior wall. Section 504.63 <br /> 5) Construction details should be provided for the AS�V segments that are e�.:^or walis <br /> (such as betwecn or along the end ef decks). <br /> bj Gxterior door�2l in the bascment of building t is �eiihin 2' of nSV�' #�1. It should be ❑ <br /> minimum of'/a-hour listed assembly. Section 504.6.3 <br /> 7) The note on Sheet A3?4 reearding roof openin�s within � feet of ASW #1 should be <br /> revised to show 10' (no opening protection or ASW need to be con[inued above the level <br /> of dic lo���er roof in this case). Section 504.6.6 <br /> 3) The exterior wing (alone the length of the exterior deck to the edge of the porch overhang <br /> above) of r�SVV #3 should continue at the 7'�' level, as the deck of Unit G21 is tloor area. <br /> Sections 50d.G3 & 207 <br /> 9) :1SW #�l should be sho�vn to continue east past its current termination along the esterior <br /> ���all for the depth of the roof o��erhang perpendicular to it (2�") at building 5 to provide <br /> complete separation. Section �Oa.6.1 <br /> 10)Door #29 in ASW #5 (2"� Icvel plan) to room I30S should be shown as a 90-minute rated <br /> assembl}'. Section 504.6.2 <br /> l l)ASW #5 should continue sou[h to thr edee of the decks (of the units in buildine 6) for <br /> complete separation from buiiding �. Section �0�4.6.1 <br /> 12)ASW #5 & 7 (same wall at this point) should continue north an additional 24" (depth of <br /> roof overhane) along the eastern exterior wall of buildine S to avoid protected �lazing <br /> along the nonhem wall of buildin, 6 in an area where it �vould conf7ict with sleepine <br /> room e�ress requirements of the units in that corner. Sections 504.6.3 & 310.d <br /> � <br />