Laserfiche WebLink
1 <br /> Ltr. Mor�an & Assoc. (B0406-006) <br /> July 31, 200d <br /> Page7 �SC� �7u��t G� � n. lYlvrc�r;n lPs�)r� SC'. 7-2Lt�O <br /> 7) Por the por[ions of enciosure [hat are above the roof level of stainvnys #3 &#8 - the walls <br /> Uiat facc/adjoin the building and doors should still be oP the minimum requimd fire- <br /> resistancc as speciGed in Section 10053.3. <br /> 3) All stainvays that do not extend to the roof surface should be shown to have (at [he <br /> hiahest elevation) an approved hatch openable to the esterior not less than 16 square feet <br /> in area. Section 100333.12 <br /> 9) The requirements and nomenclature for stainvay identification siens in accordance with <br /> 3ection 1003.3.3.13 shoufd be noted on the plans. <br /> 10)The dead end distance �vithin a corridor is measured from the ed�e of the exit door to the <br /> furdiest comer of the dead end, along a normal walking path. Some dead ends then <br /> exceed the 20' allowable. Section 1004.2.6 <br /> l l)Doors 53 within AS�V's I & l3 serve assembly amas on the roof dccks of buildings 1 & <br /> ld. They should s�ving in the opposite direction as sho�vn (the}' do not serve occupant <br /> loads of more than SO irom within the Uuilding) and be pro�rided with panic hardware. <br /> Sections 1007.3.5, 1003.2.2.Z.d S. 1003.3.1.5 <br /> 12)At least one of 1eaf of each pair of doors from Social 2oom L2a should s�vine in the <br /> opposite direction as sho�vn. Section 1003.3.1.5 � <br /> 13)Doors serving assembly occupancics (from the individual room through the egress system <br /> to the exterior exits) should be provided with panic hardware. S�ction 1007.2.5 <br /> 1�3)The elevaror lobby doors are shown as 60-minute �ssemblies on the door schedule with a <br /> smoke gasket noted in the hardware group. The minimum required door is a listed smoke- <br /> and draft-control assembly (20-minute door with `S' labei), which is not an inherent <br /> characteristic of Gre-rated doors. It should be verified that the GO-minute doors are listed <br /> smoke- and draft-control assembiies. Section 100�33.d.5 <br /> li)The roof terraces above buildings 1 S. 14 and interior assemUly occupancies should have <br /> thc maximum occupnnt loads posted and sho���n on [he plans. Section 1003.?.23.1 <br /> 16)The sun room and loun�ze on the 7'h floor in buildine 3 and billiards lounges on level G <br /> should be separated from the coiridor by rated construction and opening protection. <br /> Scction 1007.6.1 <br /> 17)The 7'h tloor in building S has a combined occupant load �reater than 50. The eeress <br /> doors serving that building segment should s�ving in the opposite direction as shawn. <br /> Sectiun L00�.3.1.i <br /> � <br />