Laserfiche WebLink
i <br /> Ltr. Mor�an & r\ssoc. (B0406-006) <br /> July 21, 200=4 <br /> Paoe 3 <br /> 13)The eeress components that serve occupant loads of 100 or more should be shown with <br /> emergency egress lighting on the plans. Section 1003.2.9.2 <br /> 19)The underside of thc `straight' stair nms should be complctely closed off or "No Storaec" <br /> signs should be postcd. Scction 1005.3.3.6 <br /> r�ccessiUilitv <br /> 1) Areas of evacuation .issistancc (r\oEA) should be provided in locations as specified in <br /> Section 110d.1. In lieu of AoEA, a written fire- and life-safety emer�ency plan that <br /> speciFically addresses the evacuation of persons with disabilities is required. This plan <br /> must be submitted for approval to the building official and fire chief. <br /> 2) OP[he 13 Type A dwellino units, 10 are in Ruilding 6, hvo are in Building 4 and one is in <br /> Building 3. Each Type A dwelling unit is required to have an accessiUle parking stall that <br /> is dedicated to it (signagc requiredl. The majoriry of accessiUle parking stalls (except the <br /> van stall) �hould therefore be located �s close to the accessible entrance of ilui;ding (i as <br /> possible (within dic pm•kir.g garage of Buildii�g �{ and/or along E. Marine view Dr.). <br /> Sections I 107.1.4 S 1107.1.fi <br /> 3) The accessible ruute oP travel from the accessible parkmg stalls �vithin the parking gsraoes <br /> to the building entry doors is shown to cross vehicular lanes of traffic. 'I'he route of�ravel <br /> should be designated and marked as a crosswalk (no parl:in�). Section l l0?.L6 <br /> d) There should be a minimum of 4' between doors #1 I in [he lobby vestibule (at a 90 degree <br /> open position) and thc exte^�r wall ro the west. Section 1106.10.3, Item 1=1 <br /> 5) Kitchen counter surfaces in all d�velling units should be shown no higher than 3d" above <br /> the flooc Sec[ion 1105.4.3 <br /> 6) The door into the bathroom of tlie one-bedroom Type A unit (Sheet A2.1) should be <br /> provided with 1S" dear from the latch ro the nearest obstruction from the pull direction. <br /> Section 1106.103 <br /> 7) 1'he distance from the centerlinc of an accessible toilet to the near wall should Ue revised <br /> from "13 inches minimum" to only "13 inches". Section 1106.1 L5.1 <br /> S) In Type B units, the lateral distance from the centerline of the water closet to the cdge of <br /> the lavatory should be sho�vn as d2" unless a lavatory compl��ine with the clearances of <br /> Section 1106.11.7 is provided. Easily removable cabinets may be provided under the lav, <br /> however details should be provided �vhich show ho�• the counter and lav will remain in <br /> place al'ter the cabinets arc remo��ed. Section 1106.27.1, Item 10 <br /> � <br />