Laserfiche WebLink
by the contractor. Daily reports shall be kcpt by the soils investigatodtester and submitted to the <br /> Public Works Inspector within 24 hours. <br /> G. All exposed ground must be reseeded within 30 days of the completion of construction. If reseeding <br /> is not practical due to weather or seasonal problems, the ground must bc co�ered�vith mulch as <br /> directed by the City Enginecr. <br /> 7. Temporary erosion control measures for construction activity must be operational prior to <br /> commencement of any clearing or earth�vork. <br /> 8. City streets are to be kept clear of dirt and debris at all times during construction. Dust suppression <br /> and street cleaning must occur as directed by the Public Works Inspector. <br /> 9. Residential street lighting within the plat shall be approved by the City Traffic Engineer. <br /> ]0. A notc must he placed on the final plat map that all lots must be served by a gravity sewer system. <br /> 1 l. Public scwer and water mains must be installed for thc project in accordance with City Design and <br /> Construction Stlndards. <br /> 12. A fire hydrant(or hydrants) capable of providing the required fire flow must be located within 350 <br /> driving fect of all residenccs in thc proposed short subdivision. Location(s)of the hydrant(s) must be <br /> approved by the City Fire Marshall, They hydrant(s) must meet City specitic�tion. <br /> 13. A one-year gunrantee is required on thc public improvement for an amount not less than 10%of the <br /> cost of constniction and shall nm for one ycar from the date of final approval. <br /> 14. As-buihs of storm sewer, sanitary sewer, and water systcros will be required to be submitted per City <br /> design and Construction Standards and Specifications for Development. <br /> I5. 1'he ne�v water main must be installed per City standards as shown on the application site plan. <br /> I G. 'Che new combination sewer m�in nmst be installed per City standards. <br /> 17. Paymcnt to Cund 3•10 is requircd in licu of ou-site detcnlion, if the downstream systcm has adequate <br /> capacity. <br /> 1 S. Parking must bc per Cit}' 'Loning Codc and City Design attd Construction Standards and <br /> Spccifications. Por the 90 single-family attached units, a rotal of 180 parking spaces nmst be <br /> providcd (2 per unit). Additional gucst parking shal( be provided ns generally sho�m in the site plan. <br /> I 9. r� pcdcstrian circulation system for the sile must be approved by the I'lanning Director and 1'raffic <br /> L'�igineer prior lo the issum�cc of any building pemiits. Walk�vays must allow pedestrians and <br /> whcelchairs to gain ensy access from sidewalks and bus stops to building entrances through the use of <br /> paths which are ph}'sically sepnrated from vehicle tr.lftic and maneuvering areas. (See tl�e city's <br /> ,� � , <br />