maintenance assurance device must be provided for the landscaping per Section 35.130B <br />of the Zoning Code. <br />13. Based upon 3080 square feet of Type V-N, unsprinklered construction, the fire flow <br />requirement is 1,500 GPM. <br />14. Access- The Uniform Fire Code requires that all new structures must provide Fire <br />Department ar,cess roads to within I50 feet of all portions of the ground tloer. Fire <br />Department access roads fFire Lanes) will provide a minimum of 20 feet in width of <br />unobstructed, all season driving surface with a minimum clear height of 13.5 feet. Fire <br />Lanes will be posted and maintained as required by the Fire Department. <br />Access as proposed on the site plan reviewed is considered acceptable <br />i 5. A tire hydrant is required within 200 driving feet, but not closer than 50 feet, of every <br />structure. The location of 6re hydrants as shown on the preliminary sewer and water plan <br />are acceptable for the proposed project. <br />16. Fire safety practices during construction must be in corr,pliance with the Uniform Fire <br />Code, 1985 Edition, Article 87, "Fire Safety During Construction." <br />17. Fire Alarm System: M approve automatic fire detection system must be provided as <br />required by Chapter 16.76 of the Everett Municipal Code. <br />Plans for such system must be submitted to the Fire Marshal for review and approval prior <br />to installation. Submittal shall include cut sheet of all equipment intended for use. <br />Appropriate trip tests, witnessed by a Fire Department inspector must be perf'ormed prior <br />to final acceptance of the system. <br />Fire alarm systems must be installed under pertnit of the City of Everett Building <br />Departmer.t. Electrical inspectors and approval are required prior to calling for <br />acceptance tests. Call 259-8810 for pernut infortnation <br />I8. A portable fire extinguisher with a minimum UL rating of 2A must be provided within 75 <br />feet travel distance on each floor of all portions of each building during construction and <br />priorto occupancy. <br />19. PREMISE IDENTIFICATION AND ALL REQUIRED FIRE DEPARTMENT <br />ACCESS ROADS AND FIRE HYDRANTS MUST BE IN SERVI�C:E PR[OR TO <br />COMMENCEMENT OF CONSTRUCTION. <br />20 Premise Identification- The premises must be cleazly identi6ed by the correct address a� <br />the street entry. Buildings must be clearly identified so as to be visible and legible from <br />the access road. Each suite must be clearly identified so as to be visible and legible from <br />the access road. <br />Zl. When access to or within a structure or an area is unduly difficult because of secured <br />openings or where immediate access is necessary for life saving or fire-fighting purposes, <br />the Fire Department may recommend or require a key box to be installed in an accessible <br />location. A rapid entry system may also be desirable in order to avoid unnecessary <br />damage while making entry to any building durin¢ ac� emergency situation. <br />Please call 259-8726 for further information. <br />