My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2720 W MARINE VIEW DR SCOTT HERALD CHILD CARE CENTER 2018-01-01 MF Import
>
Address Records
>
W MARINE VIEW DR
>
2720
>
SCOTT HERALD CHILD CARE CENTER
>
2720 W MARINE VIEW DR SCOTT HERALD CHILD CARE CENTER 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/27/2019 8:44:29 AM
Creation date
2/27/2017 6:33:39 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
2720
Tenant Name
SCOTT HERALD CHILD CARE CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
maintenance assurance device must be provided for the landscaping per Section 35.130B <br />of the Zoning Code. <br />13. Based upon 3080 square feet of Type V-N, unsprinklered construction, the fire flow <br />requirement is 1,500 GPM. <br />14. Access- The Uniform Fire Code requires that all new structures must provide Fire <br />Department ar,cess roads to within I50 feet of all portions of the ground tloer. Fire <br />Department access roads fFire Lanes) will provide a minimum of 20 feet in width of <br />unobstructed, all season driving surface with a minimum clear height of 13.5 feet. Fire <br />Lanes will be posted and maintained as required by the Fire Department. <br />Access as proposed on the site plan reviewed is considered acceptable <br />i 5. A tire hydrant is required within 200 driving feet, but not closer than 50 feet, of every <br />structure. The location of 6re hydrants as shown on the preliminary sewer and water plan <br />are acceptable for the proposed project. <br />16. Fire safety practices during construction must be in corr,pliance with the Uniform Fire <br />Code, 1985 Edition, Article 87, "Fire Safety During Construction." <br />17. Fire Alarm System: M approve automatic fire detection system must be provided as <br />required by Chapter 16.76 of the Everett Municipal Code. <br />Plans for such system must be submitted to the Fire Marshal for review and approval prior <br />to installation. Submittal shall include cut sheet of all equipment intended for use. <br />Appropriate trip tests, witnessed by a Fire Department inspector must be perf'ormed prior <br />to final acceptance of the system. <br />Fire alarm systems must be installed under pertnit of the City of Everett Building <br />Departmer.t. Electrical inspectors and approval are required prior to calling for <br />acceptance tests. Call 259-8810 for pernut infortnation <br />I8. A portable fire extinguisher with a minimum UL rating of 2A must be provided within 75 <br />feet travel distance on each floor of all portions of each building during construction and <br />priorto occupancy. <br />19. PREMISE IDENTIFICATION AND ALL REQUIRED FIRE DEPARTMENT <br />ACCESS ROADS AND FIRE HYDRANTS MUST BE IN SERVI�C:E PR[OR TO <br />COMMENCEMENT OF CONSTRUCTION. <br />20 Premise Identification- The premises must be cleazly identi6ed by the correct address a� <br />the street entry. Buildings must be clearly identified so as to be visible and legible from <br />the access road. Each suite must be clearly identified so as to be visible and legible from <br />the access road. <br />Zl. When access to or within a structure or an area is unduly difficult because of secured <br />openings or where immediate access is necessary for life saving or fire-fighting purposes, <br />the Fire Department may recommend or require a key box to be installed in an accessible <br />location. A rapid entry system may also be desirable in order to avoid unnecessary <br />damage while making entry to any building durin¢ ac� emergency situation. <br />Please call 259-8726 for further information. <br />
The URL can be used to link to this page
Your browser does not support the video tag.