Laserfiche WebLink
ENallvEEIcmro / Filour sEl y1rE5 zrEPA/zrmEHT <br />April 9, 2007 <br />Mr. Bob Murphy <br />P.O. Box 3284 <br />Everett, WA 98213 <br />RE: Owner: <br />Job Address: <br />Plan Check No <br />Dear Mr. Murphy: <br />Murphy Building Co., Inc. <br />3018 W. Marine View Drive <br />B0702-004 <br />In response to your application for a construction permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only. Additional revisions, or additions, may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the <br />2003 International Building Code, as amended by the State of Washington and adopted by the <br />City of Everett and the Washington State Energy C.xle, 2004 Edition, unless stated otherwise. <br />In order for the processing of your application to continue, it will be necessary to provide <br />the Building Division with two complete new sets of drawings reflecting the corrections <br />requested. <br />1. At least one story containing dwelling units or sleeping units intended to be occupied as <br />a residence shall be provided with an accessible entrance from the exterior of the <br />building and all units intended to be occupied as a residence on that story shall be Type <br />B units. IBC 1107.6.2.1.2 & 1107.7. <br />2. An exit enclosure in accordance with IBC 1019 is required to protect the stairway. <br />3. Please provide the proposed construction type. Type VA would be required with the <br />proposed 903.3.1.2 fire suppression system. IBC Tbl. 601. <br />4. Please provide dimensions from building lines to property lines on the north and south <br />sides. If less than 5'-1", provide detailing for one -hour fire -resistive construction for <br />the walls rated for exposure from both sides. IBC 704.5. <br />5. Please provide detailing necessary to verify one -hour fire -resistive construction for all <br />bearing walls and the roof/ceiling assembly. <br />6. Please provide detailing necessary to verify one -hour fire -resistive construction for all <br />Boor/ceiling assemblies (including decks). These must be compatible with TH Boor <br />joists. Provide testing agency I.D. numbers. These must also provide a sound <br />transmission coefficient of 50 or greater. <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 <br />DEDI PLNo1MSI RUI1ER1R07024N (3019 W MARINE VIEW DR) <br />