Laserfiche WebLink
' Altinay & Associates Inc. David N. James, AIA <br /> September 20, 1988 <br /> page 2 <br /> 3. We did not encounter any water table. <br /> 4. We understand that the proposed buildings will be located <br /> with at least a 25' set back from Rainier Drive and a <br /> 10' set back from Madison Street. <br /> C. RECOMMENDATIONS: <br /> 1. Footings should be placed on or within the suitable <br /> material. '(Please see attachments) . <br /> 2. Special foundations are not necessary. Squw_e and <br /> continuous footings may be used. <br /> 3. SUHGRADE PREPARATION: <br /> Immediately prior to the placement of footings, the <br /> . entire width of subgrade should be cleaned of organic <br /> debris and loose material. <br /> All depressions and cavuties should be filled in and the <br /> subgrade regraded. <br /> Site soils, except for organic material and topsoil may <br /> be used for backfilling under structures, parking lot and <br /> behind the rockery. <br />