My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3116 ROCKEFELLER AVE 2016-01-01 MF Import
>
Address Records
>
ROCKEFELLER AVE
>
3116
>
3116 ROCKEFELLER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2017 6:39:42 PM
Creation date
2/27/2017 1:45:32 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3116
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ • <br />� � <br />4. The new exterior walls that are located Iess than 20 feet from the northern properry <br />line should be of minimum one-hour fire-resistive construction. The existing walls <br />and structure supporcing any new exterior walis required to be of one-hour fire <br />resistive construction should be revised to one-hour walls as well. Section 503.21 8c <br />Table 5-A <br />5. The new windows located lAss than 10 feet from the northern property line should be <br />shown as 45-minute fire rarcd assemblies. Table 5-A. <br />6. Openings such as soffit or exhaust vents are not permitted less than 10 feet from the <br />northern property line. Table 5-A. <br />Construction <br />1. Guardrails should be shown not less than 42" in height. Section 509.2 <br />2. A guardrail should be provided at the exterior wall where the stairs are adjacent to a <br />window. Section 509.1 <br />3. The window within the stair enclosure at the main level should be shown as safety <br />glazing. Section 2406.4 <br />4. The shed dormer in Section A/4 should be shown with a minimum of 1" of <br />ventilation air space above the insulation. Calculations should be provided showing <br />the required attic ventilation. Section 1505.3 <br />5. Wall Sections B/5 and D/5 should be removed as they do not apply. <br />6. Typical Wall Section A/5 is not accurate, it should be revised to show the full <br />basement retaining wall condition. <br />Exiting <br />1. The new stair serves more than one adjacent level and should therefore be provided <br />with a stair enclosure per Section 1005.3.3.1. Based on that section the following <br />comments appty: <br />a) The stair enclosure should have minimum one-hour fire-resistive construction. <br />Section 1005.33.2 <br />b) The enclosure should be separated from the interior spaces with minimum 60- <br />minute fire-rated assemblies having maximum 450 degree temperature-rise <br />labels. Section 1005.3.3.5 <br />c) A barrier should be provided at the first story which prevents persons from <br />accidentally exiting into the basement. Section 1005.3.3.4 <br />DI:DVPLNIXMYTRII EFIJ I IA ROCAf:FE1.L[R Z <br />
The URL can be used to link to this page
Your browser does not support the video tag.