My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3506 ROCKEFELLER AVE 2018-01-02 MF Import
>
Address Records
>
ROCKEFELLER AVE
>
3506
>
3506 ROCKEFELLER AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2022 7:57:54 AM
Creation date
2/27/2017 2:08:32 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3506
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
$re Dendy f:kdf' c I <br />PO Box 704 Vvv�J -Cr-3 <br />Lynnwood, WA 98046-0704 <br />3 - 3( -dq <br />Todd Ade <br />3506 Rockefeller <br />Everett, WA 98201 <br />425 257-0540 <br />Dear Mr. Ade <br />This letter is the inspection report for your property at 3506 Rockefeller. <br />I inspected the properly on 3.31-2009 and found numerous code violations. These issues need to be <br />addressed for me to certify the wiring. Some wallboard will have to be removed when a final <br />certification inspection is done. Here is my list of corrections visible at this time. <br />1) New sub panel in the basement needs a new feeder wire. (3 conductors with ground). As we <br />discussed this panel may be eliminated and the circuits fed from existing panels in the <br />basement. <br />2) In the existing panels, romex installed needs to have connectors. Unused breaker slots need <br />blank covers. <br />3) Sub panel adjacent to main panel in basement needs ground wire and ground bus installed. All <br />ground wires in this panel must be attached to this new bus <br />4) Breakers property sized for the wire must be installed. <br />5) Holes for wiring through framing members must be drilled in the middle of the studs and wire on <br />parallel runs stapled every 4.5 ft <br />6) Hot water heaters need #10 awg installed (this would correct the over sized breakers on these <br />circuits). <br />7) The junction box to the right of the sub panel needs to be removed or covered. <br />8) Bare bulb light fixture in closet needs to be removed. <br />9) All junctions (splices) and devices must be enclosed in j-boxes. <br />When your perils are in place and the corrections are completed, call me for a final certification of the <br />wiring. If you decide you want us to do the wiling we will gel the electrical permit. <br />Thank you, <br />! race Anderson <br />$ee Dandy melee r,'t <br />
The URL can be used to link to this page
Your browser does not support the video tag.