Laserfiche WebLink
June 26, 2007 <br />?NG/NEER/NEi / PL/BL/C 5E/�f�/CES OEPARTAlENT <br />Ms. Brianna Miles <br />2813 Rockefeller Avenue <br />Everett, WA 98201 <br />Subject: ProjecL• <br />Job Address: <br />Plan Check No: <br />Dear Ms. Miles: <br />Fagerlie <br />3721 Rackefeller Avenue <br />CO510-006 <br />In response ro your application for a construction perm}t, your pla��s have been examined and <br />you are advised that die issuznce of a permit is bemg withheld for tl�e reasons listed Uelow. <br />Thcse comments address building issues only. Add�tional revisions or additions may be <br />required by odier depanments (such as Utilities, Planning or Fire). All references refer to the <br />2003 International Residential Code, as amended by the State of Washington and/or <br />Washington State �nergy Code 2004 Edition, and adopted by the City of Everett, unless stated <br />od�envisc. <br />In order for tlie processing of your application to continue, it will be <br />necessary to provide tlie Butlding Division witli rivo complete new sets of <br />drawings retlecting tlie corrections requested. <br />The following are d�e correction from our previous letter: <br />Item N2: Provide size and location of wLole house fan. Table 3-2 of Uie Washington <br />State Ventilation and Indoor Air Qualiry Code (WSVIAQC) specifies for a 3-bedroom <br />residence with 1595 square feet the requircment for tlre whole house fan is minimum 80 <br />cfm, maximwn 120 cfm. The plans show 5820 cfm. <br />Item #3: Provide detail for rigid insulation installed on d�e exterior of below-grade walls. <br />Sl�ow liow the insulation is protected from exposure to ultra-violet light and impact. <br />Item N4: Stairs arc required to Ue 3'-0" clear width. The plans sho�v 3'-4" from the face <br />of the concrete wall to the face of the framing, which would leave �k" for gypsum <br />wallboard. <br />Item N9: Handrails sl�all Ue continueus for the entire length of tUe run/R311.5.6.2 IRC. <br />Item /t10: The following shall be considered spccirc hazardous locations for Qie pu�ose <br />of glazing: (Pcr R308.4 IRC) <br />1. Glazing in swinging doors <br />5. Glazing in doors and enclusures for .... st:o�vers. <br />6. Glazing in �n individual fixed or operable panel adjacent to a door where the <br />ncarest vertical edge i� �vithin a(24-inch arc or a door in a closed position). <br />CITY OF EVERETI' • 3200 Cedar Street • Everett, WA 98201 •(42�) 7.57-8800 • Fax (425) 257-8856 <br />Uf:OIIPINCAMSTR/IIPJLAIAN:ltl510U06 p77I ROCAGPLLLIIR AVW�I <br />� <br />