My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2102 ROSS AVE 2018-01-02 MF Import
>
Address Records
>
ROSS AVE
>
2102
>
2102 ROSS AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 8:50:57 AM
Creation date
2/27/2017 2:51:35 PM
Metadata
Fields
Template:
Address Document
Street Name
ROSS AVE
Street Number
2102
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
27. Any security fence erected around the construction site shall be located so as to not obstruct any <br />existing hydrant, fire protection equipment, or Fire Department access. If Fire Department access is <br />obstructed, gates or other openings shall be provided for access. <br />28. Premises shall be clearly identified by the correct address at the street entry. Buildings shall be clearly <br />identified so as to be visible and legible from the access road. Individual apartments and suites, where <br />applicable, shall be clearly and legibly identified from the access road. <br />29. Based upon 42,000 square feet of Type V-B, sprinklered construction, the fire flow requirement is 2,750 <br />gpm. Lower fire flows can be allowed with certain alternative construction types, subject to approval by <br />the Fire Department. <br />30. When the required fire flow is over 2,500 gpm, the fire hydrant shall be served by a main that loops <br />around the building or complex of buildings and reconnects back into a distribution supply main. Three <br />hydrants are required on the loop: one east, one west, and one in the middle of the north side of the site. <br />31. A portable fire extinguisher with a minimum U.I.. rating of 2-A:10-B:C shall be provided witnin 75 feet of <br />travel on all floors of each building during construction and prior to occupancy. <br />32. An approved automatic fire detection system shall be provided as required by City Ordinance No. 3021- <br />07, Chapter 16.76, of the Everett Municipal Code. <br />Plans for such system shall be submitted to the Fire Code Official for review and approval prior to <br />installation. Submittal shall include cut sheets of all equipment intended for use. Appropriate trip tests, <br />witnessed by a Fire Department Inspector, shall be performed, along with a certificate of completion, <br />prior to final acceptance of the system. <br />Fire alarm systems shall be installed according to NFPA Chapter 72. Installation of fire alarm <br />components, including basic wiring, may not commence before plans are approved by the Fire <br />Department Plan Reviewer. Fire alarm drawings must be professionally rendered, in sufficient detail, <br />and must be internally consistent. Riser diagrams must match installation plans and load calculations. <br />Components must be listed and approved for use together. Changes to plans must include new <br />drawings and calculations and must be approved by the Fire Department Plan Reviewer prior to <br />installation. Fire alarm installation is subject to field inspection by a Fire Department Inspector. An <br />approved set of plans and the Engineering & Public Services Department electrical permit must be <br />present for any installation inspection. <br />Fire alarm systems shall be installed under permit of the City of Everett Engineering & Public Services <br />Department. Electrical inspections and approval are required prior to calling for acceptance tests. Call <br />(425) 257-8810 for permit information. <br />The absence of working phone lines for the alarm system will be cause for postponing Fire Department <br />inspection and testing and shall result in denial of occupancy. <br />33. An approved automatic suppression system shall be provided as required by City Ordinance No. 3021- <br />07, Chapter 16.76, of the Everett Municipal Code. The system must include a mechanical water gong <br />bell. <br />Plans for any such system shall be submitted to the Engineering & Public Services Department for <br />examination and approval. Such plans shall include plans for the underground mains that will supply the <br />sprinkler system. <br />
The URL can be used to link to this page
Your browser does not support the video tag.