Laserfiche WebLink
. <br /> . � � �.� i <br /> Plan Chcck Nu. 59626 <br /> August 4, 1998 <br /> Page 2 of 2 <br /> 10. Specify size of roof sheathing <br /> 11. Specify wall height on each floor. Show from top cF slab-on-grade to top of doublc top plate, <br /> and from finished floor at lofi to double top plate. <br /> 12. Show finished grade on section view. Concrete supporting wood is required to extend min. 6" <br /> above it,e adjacent finished grade. ' <br /> 13. Veri�}� ri�u joist size and material (some wood "I juist" manufacturer's do not allow solid sawn <br /> lumber to be used as rims if engineered floor joisu ue used). <br /> Provide a response letter showing where each item in this correcdon letter is addressed on the plan <br /> set. • <br /> Upon resubmital of the drawings, your application will be given priority and plan review will <br /> commence. <br /> All required submittals shall bP uf sufficient detail and contain sufr7cient info:u�ation to ensure that the <br /> proposed structu:e will be constructed in complian;,e with all adopted codes. <br /> Sincenly, <br /> � • <br /> J Heilman <br /> Development Technician <br /> 1H:jt:59626 . <br /> r• <br /> tf <br /> I�� }� <br />