. • <br />�r% <br />� PUBLIC WORKS <br />, <br />C�'y� �t�r'�` <br />• <br />b. A new guard, if required by an elevation greater than 30 inches above existing grade, <br />should be detailed in elevation and section, per the previous correction letter, comment <br />9. Guard shown in elevations and detailed in Ramp Details 5/A3 <br />c. The maximum diHerence of 30 inches to adjacent grade should be noted on the <br />drawings if the guard is deleted from the exterior stair or ramp. Guard is not deleted <br />✓ d. The risers and treads of the existing exterior stairs should be dimensioned, per the <br />previous corrections letter, comment 10. Exisling exter�or stairs tread and riser <br />dimensions added for stairs at door #5 on Proposed Floor Plan 1/A2 <br />e. Handrails are required on both sides of exterior stairs and ramps, per the previous <br />� corredion letter, comment 8. Handrail, added on bolh sides of all exterior stairs and <br />ramps <br />f. Handrails should be detailed in section and dimensioned in height, per the previous <br />�� corredions letter, comment 8. Handra�is deta�led and dimensioned in Ramp Details <br />5/A3 and Handrail Detail 6/A3 <br />g. New construction should be shown as dark lines to differentiate it from existing (light <br />� lines), so that labels for existing can be removed from the drawings, and new work is <br />clearly highlighted; e.g. new doors, new hand rails, new stairs, and new windows, per <br />the previous corrections letter, comment 2. Line weights have been changed to uUlrze <br />the light = existing, dark = new graphic vocabulary on plans and delai!s ihroughout <br />✓ h. Details, materials and dimensions are required for all new construction, per the previous <br />corrections letter, comment 3. Thi, comment is addressed by the add�tion nf Proposed <br />Framing sheet A4 and revisions to plans and details lhrouahout the existing plan set <br />" 4. A section is required through the ceiling to indicate the construdion of new drywall, per the <br />attached NWCB technical ducumeni 400-200, or other method of construdion for an existing <br />Ceiling retrofit. Ceiling is not a retrofit, exisling ceiling to remain as shown in details A&B/A4 <br />� 5. Where wall or ceiling cavities are expose^ during construction, the heated area requires <br />insuiation to be replaced and shown on th�� drawings as minimum R-3.0, per WSEC 1132.1. <br />New R-30 insulahon i� called out m detadti A8B/A4 <br />Deferred Permits <br />1. Exterior business signage should be submitted separately on a deferred permit for review by the <br />planning and building departments. Noted by owner <br />���dditionally, some work has be�n added to Ihe project at lhe exisling brick fireplace where a portion o( <br />ihe exisling ch�mney has been removed and braced up. See elevation mark on Proposed �loor Plan <br />on sheet A2 and Details 7&A/A3. <br />Upon submission of two inserC sets of revised drawings reFleding che corrections requested, your <br />application will be processed. Applicable codes indude the 2009 Ini. rnational Building Code (IBC), the <br />2009 Intemational Fire Code (IFC), the 2009 Intemetional Mechanical Code (]MC), the 2009 <br />Washington State Energy Code (WSEC), the 2003 Accessible and Usable Buildings and Facilities <br />A1i7.1-2003 ;ICC/.;NSI) as adopted by Lhe by the State of Washington. These comments adoress <br />building issues o�ly. Revisions or additions may be required by other departments (such as Utilities, <br />Planning or Fire). <br />3/,� <br />