My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10330 4TH AVE W 2016-01-01 MF Import
>
Address Records
>
4TH AVE W
>
10330
>
10330 4TH AVE W 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2017 6:59:24 PM
Creation date
3/7/2017 11:31:01 PM
Metadata
Fields
Template:
Address Document
Street Name
4TH AVE W
Street Number
10330
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
South Pointe Assisted Living Facility. <br />Storm Drainage Report. <br />DRAINAGE CRITERIA <br />The calculations for sizing the foilowing described storm water facilities are based on <br />the following criteria: <br />Detention Storage: 100 ye;�r�,o ye °U24 hou�pre-de� oped release <br />10 year, 24 hour developed storm with <br />10 year, 24 hour pre-developed release <br />2 year, 24 hour developed storm with <br />'/Z - 2 ye�r, 24 hour pre-developed release <br />Existing Conditions: <br />Proposed Conditions: <br />Soil Type: <br />SCS Curve Number: <br />(Developed Conditians) <br />Pervious area = 0.48 Acres <br />Impervious area = 0.07 Acres <br />Total area = 0.55 Acres <br />Pervious area = 0.22 Acres <br />Impervious area = 0.33 Acres <br />Total area = 0.55 Acres <br />SCS Group C <br />Pervious C�: 86 <br />Impervious C�: 98 <br />RUNOFF CONTROL <br />In compliance with the City of Everett Design Standards and the Washington State <br />Department of Fisheries, surtace runoff will be controllad by means of an on-site <br />faciliry. The on-site drainage runoff control facility was designed to control the <br />discharge of peak runoff rates from the pr�ject siie under new developed conditions. <br />The paved areas will be graded so that surface runoff is directed towards a catch basin. <br />Flow will be collected in an underground facility and controlled by a"Flow Control <br />Manhole". The multiple orifice outlet is sized for a staged storage release. An overflow <br />bypass is provided in the event of control structure failure or for storm events that <br />exceed the design criteria. <br />WATER QUALITY CONSIDERATIONS <br />On site paved areas exposed to vehicular traffic is relatively small at less than 5,000 <br />square feet. Wster quality control will be provided by means of dead storage in each of <br />the four on-site storm retentfon system manholes. The depth uf the manholes has been <br />increased to a minimum cf 36" below the invert elevation to allow for the dead storage. <br />
The URL can be used to link to this page
Your browser does not support the video tag.