My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10330 4TH AVE W 2016-01-01 MF Import
>
Address Records
>
4TH AVE W
>
10330
>
10330 4TH AVE W 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2017 6:59:24 PM
Creation date
3/7/2017 11:31:01 PM
Metadata
Fields
Template:
Address Document
Street Name
4TH AVE W
Street Number
10330
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
363
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />��'� 19. Interior openings into corridors aze required to be protecteci as set forth in Section <br />1005.8. Self-closing or automatic closing twenty-minute rated door assemblies <br />properly gasketed should be provided. Other openings aze limited to 3/4-HR rated <br />fixed glazing and shall not exceed 25% of the azea of the common wall. <br />1�20. Accessible doors shall have maneuvering clearances per Secdon (106.10.3. This <br />item applies to the door leading to living room 03. <br />�(�(�%i� 21. All ezterior exiu which are located adjacent to accessible areas and within 6 inches <br />of grade shall be accessible. Secdon 1104.3. <br />�,�� 22. On any floor where water fountains aze providu�, at least 50 percent, but in no case <br />less than one shall be accessible. Section 1104.3. <br />23. Controls, operating mechanisms and hazdwaze shall be accessible in accordance with <br />Section 1106.3. <br />V 24. Alarm systems shall include both audible and visible alazms and shall be located per <br />Section 1105.4.9. <br />V��� 25.One in every eight accessible pazldng stalls, but not Ic:ss than one pazking stall, shall <br />comply with the van puldng space requirements in Section 1107.1.5. <br />/�%��'�� 26. An accessible route of travel must be provided from the main building entrance to the <br />public way. Secdon 1103.2.2. <br />d 27. Supply and dcain Gnes under accessible lavatories must be insulated. Sec. <br />1106.11.7.4. <br />�(,i��%'� 28. Rockeries must be engineered if ove,r 4'-0" high. If a walking surface is adjacent to <br />top of wall ovr 30" high then a gua�drail per Sec. 509 is required. <br />�jj�? �9. Please provide size and locations of kitchen exhaust fans . nd room outdoor air inleu <br />per VIAQ code. <br />30. Indicate smoke detectors per Sec. 313.8.1.1. <br />�,��(C� 31. Frames for corridor relites must have a 3/4-HR fire nting. <br />�32. Slab edge insulation must be RIO minimum. <br />