Laserfiche WebLink
� <br />Prepared by Connell Design Group 12/26/00 <br />Code Response Letter <br />Note: Responses to comments are in bold font. <br />RE: VSI Inc. plan reviews no. 80011-020 <br />BUILDING <br />� <br />� rtTIJ = Tb�J `j <br />L�. <br />1, dased on the site plan, the ncrthem and southem eMerior walls are less than 20 feet from the <br />property lines. Those walls should be shown as listed, one-hour fire resistive assemblies. The <br />listing should be shown on the plans. <br />We have added one hour rated conatructfon assembly per'James Hardie' Building <br />Products Aaaembly N4 as approved in NER-405 repoR For the North and South walls. <br />See atfached aheet A2.0. <br />2. The roof/ceiling should be a listed one-hour fire resistive assembly. Section 709.4.1. <br />The documents have been revised to show (2) layers of 5/8" type 'X' GWB on the roof <br />joists (ceiling) for a one hour assembly. See aheeb A4.0 and A6.0. <br />3. The analysis of the roof by the Engineer of Record states that the Existing Roof does not <br />meet Structural requirements of the 1997 UBC. If the stresses in the roof inembers exceeded <br />one and one half times the working stress or stresses allowed in the UBC, the building will be <br />classified as'dangerous' per the definition is Section 302 of the 7997 Abatement of <br />Dangerous Buildings code. All buildings or portions thereof which are determined to be <br />dangerous shall be abated by repair, rehabilitation, demolition or removal. Any required <br />repairs shouid be specified by the Engineers of Record and shown on the plans. Section <br />106.3.4.1. Note that the roof inember diagram in the engineers' report does not depict the <br />actual roof constructior., as the ceiling joists do not attach to the roof rafters. The actual load <br />path of stresses through the plates and studs should be clarified. <br />We will comply. Please see revised drawings (addi?ional aheet added) 31.3, and <br />revfsed calculations. <br />4. The handrail extension at the bottom of the interior stairs should be a minimum of 23". <br />Section 1003.3.3.6 <br />We have added the handrails with the 23" extension to the floor plan, see attached <br />sheet A2.0. <br />5. The Water Heater shouid be shown strapped to the structure at the top and bottom of the <br />tank. Sectior. 308.1, UMC <br />We have added a note stating the Water Heater shall be seismically strapped to the <br />structure at both the top and bottom oi the tank, sea sheet A2.0. <br />6. The doors on the Second Floor (Type B) should be caoable of being opened so that the clear <br />width of the opening is not less than 32". Section 11-6.10.2 <br />The doors on the Second Floor were changed to 36" vride doors, see sheet A2.0. <br />7. The slope of the elevated walkway should be shown as not more than 1:20. Section <br />1106.4.3. <br />