My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5208 S 2ND AVE 2016-01-01 MF Import
>
Address Records
>
S 2ND AVE
>
5208
>
5208 S 2ND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2017 6:25:39 PM
Creation date
3/8/2017 12:22:35 AM
Metadata
Fields
Template:
Address Document
Street Name
S 2ND AVE
Street Number
5208
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f <br />� <br />This walkway fs not a required aeces�IbM entrylwalkway. Ths second floor k Isss than <br />3,000 sq. R. and not roquirod to be acc�sslbN per WAC61-40. <br />8. The required under-fioor ventilation of 1 sq. ft. ot net free ventilation for each 150 sq. R of <br />area should be shown on the plans. Note that there may not be any vents on the Northem <br />exterior wall (per Table 5-A 1 Section 2306.7 <br />We wlll comply, see Under-floor Ventilatlon Note on Sheet A2.0. <br />9. The bottom of fioor joists should be shown at a minimum of 18" above undtrvfloor grade and <br />beams at a minimum of 12". Section 2306.3 <br />The floor jofsb and crawl spacs aro exfstinp condltlons. New columns and bsams aro <br />bNng installsd to brinp the strueturo to cod� compli�ncs. To ezcavats th� erawl spac� <br />wkh the exktiny foundation condkions would be eeonomicatly and structurally <br />Infeasibls. Ws have rovised ths documents to show a min. of 12" clear x 4'-0" wlds <br />sMp below new bsams � Grid Lins'B', sse shset 31.0. <br />10. An access door to the under-floor area should be shown on the plans. The minimum size is <br />78" x 24". Section 2306.3. <br />We will eompy. The new door to ths crawl space la shown on the flrst floor pian and <br />Structural Framing plan undar ths stalr, ss� aheets A2.0 and 31.0. <br />11. It should be clarified how ventilation requirements are met as an HVAC system is not shown <br />on plans and the windows on the North wall are non-operable. Section 1202.2.1 <br />Ths design/build mechanicat contractor will addross ths ventilation rsqulromenb <br />based an flxed wfndows on the North sids oi ths building. <br />Civil Site Review Redlines: <br />1. Note requirir�g ADA parking stall to be relocated to the north end of :�ie block. <br />2. Storzn syste�n redesign. <br />These items have been changed per the comments and revfsed on Shest A7.0. <br />�L <br />
The URL can be used to link to this page
Your browser does not support the video tag.