Laserfiche WebLink
� Robert K. Royce <br />���o�, Jamie G. Johnson � <br />� <br />onle July 1� 1975 <br />�ur��c, IOOF Building .. .. i.���. . �.., . � __ .i�., �... <br />5217 South Second <br />Everett, taashington <br />The above referenced building was inspected by t}iis department, on <br />June 3C, 1975, and several discrepancies to the City IIuilding C�des <br />were found. <br />The building is of unprotectedo�oodframe (type V-N) construction <br />containing a total of 12, 550 square f.e��t of area on all fluors and <br />the last known usages were that of retail and residental apartment <br />on the first and second floors and assembly use on the third floor <br />which consti:utes a mixed occupancy of �, F, and H use groups. <br />Section 50? rea,uires that the F,znd H occupancies be separated <br />from B occupancies by a nne-hour fire resistive separation in compliance <br />with table 43C, item 27 including footnote 19. <br />However, Group B occupancies of fire resistive wood frame co;istructior. <br />is limited to two stories. Therefore, assembly (b) use would not be <br />permitted on the third floor. <br />The following discrepancies and other corrective work will have to be <br />completed before the bui].ding will conform to the code requirements <br />for a new buildin9 and occupancy permited. <br />1. The building will have to be made one-hour fire resistive, <br />throughout, this includes all floors, ceilings, columns, <br />posts, beams, iieaders, girders, joists, interior walls, and <br />exterior and interior far_es of all exterior walls, as set <br />fort;� in tables 43 P.. B. and C., or the building can be <br />equipped throughout, with an automatic fire extinquishing <br />system as set forth in chap�er 39 of the building code. <br />2. Exits will have to be orovided in allareas on ail floors in <br />complainace with Chapter 33 of the cuilding code. This <br />requirement cannot be determined unt;l such a time as a <br />floor plan is provided showing the proposed uses of the <br />Uuilding. <br />3. All balconies, stairs, landings, corridors, guard rails, and <br />hand rails shall. also complr with Chapter 33 of the code. <br />d. All occupied areas shall be provided wich natural li9ht and <br />venti:Lation by means of windows as set forth in Part III of. <br />the co,9e. Approved complying mechanical systems may be use:: <br />in liecv of windows. <br />5. The kitchen must r.omply with codes as a commercial kitchen <br />and be spproved b�• the Snohomish County liealth District. <br />