My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4917 S 3RD AVE 2016-01-01 MF Import
>
Address Records
>
S 3RD AVE
>
4917
>
4917 S 3RD AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2017 11:59:11 AM
Creation date
3/8/2017 1:12:40 AM
Metadata
Fields
Template:
Address Document
Street Name
S 3RD AVE
Street Number
4917
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
141
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
page 2 <br />491i 3rd <br />January 2, 1979 <br />3a1. Level all floors. <br />;a2. Construct solid concrete or masonry foundations -- <br />as set forth in Chapter 29. <br />3a3. All foundations shall be of a size as set forth in <br />table 29-a for two story buildings. <br />3a4. Provide under floor ventilation in compliance with <br />Section'2517 (c) 6. <br />3a5. Remove and replace all deteriorated wood. <br />3aG. Remove and replace all untreated wood in contact with <br />3a7 <br />3a8. <br />3a9. <br />3a10 <br />masonry or concrete and replace with approved pressure <br />treated wood or foundation grade cedar. <br />Remove all wood in contact with ground and replace <br />with materials as set forth in 3a6. Remove all dirt <br />within six inches of all wood. <br />Regrade ground at �aest wall to comply with 3a7. <br />Provide attic ventilation as s�t forth in 3205(c). <br />Provide pier blocks or footing:: of sufficiant size <br />to carry imposed vertical load�. <br />3a11. Provide foundation ventilation in complience with <br />Section 2517. <br />3a12. Foundation sill plates shall be anchored as set forth <br />in Section 2907(c). <br />3a13. SmoY.e detectors shall be provided as set forth in <br />Section 14].3. <br />3a14. All rooms shall be provided with windows <br />in complete compliance with Sections 1309 <br />3a15. Shower and tuU areas shall be finished as <br />or openings <br />and 1305. <br />set forth <br />in Section 1711. <br />3a1G. Remove and replace all hazardous porches, decks, <br />and stairs. Provide hand an3 guard rails in compliance <br />��rith Section 171G and 3305 (a) . <br />3a17. Stairs shall comply with Section 3305(b) and 3305(c). <br />3a16. Provide a vented hood or fan vented to the outside <br />3a19. <br />3a20 <br />3a21 <br />3a22 <br />3a23 <br />3a24 <br />3a25 <br />over the range space. <br />All floor, ceiling, and roof joists and rafters shall <br />be of size as set forth in Chapter 25. <br />Floors shall be leveled tru� and plumb. <br />��alls shall be aligned true and plumb. <br />7�11 damaged and deteriorated exterior and interior <br />finishes shall be replaced. <br />'Phc roof shall be removed and replaced. <br />The building shall be madc weather and damp proof. <br />Allother.such provisions of the IIuilding and Mechanical <br />Co�e which pertai.n. <br />Yours trul <br />��Z�1n�� �, �� <br />Jamie G. Johnson <br />In�pectio�i Superviscr <br />
The URL can be used to link to this page
Your browser does not support the video tag.