My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5831 S 3RD AVE 2016-01-01 MF Import
>
Address Records
>
S 3RD AVE
>
5831
>
5831 S 3RD AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2017 2:58:36 PM
Creation date
3/8/2017 1:34:27 AM
Metadata
Fields
Template:
Address Document
Street Name
S 3RD AVE
Street Number
5831
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
December 12, 1995 <br />�U6�/� K/O« <br />Langus Homes, Inc. <br />2209 Sth Street <br />Everett, WA 98201 <br />RE: Owner: Langus Homes, Inc. <br />JobAddress: mr,r S$3� Lq�,yw�� <br />Plan Check No.: 50244 <br />Dear Mr. L,angus: <br />In response to your application for � construction permit, your plans have been examined and you are <br />advised that the issuance of a permit is being widiheld for the reasons listed below. These comments <br />address building issues only, additional revisions or additions may be required by other departments <br />(such as Utiliues, Planning or Fire). AI! references refer to the 1994 Uniform Building Code, as <br />amended by thc State of Wasnington ar�d/or �Vashington State Energy Code 1995 Edition, unless stated <br />otherwise. <br />1. Plans do not meet prescriptive reyuirements for lateral bracing per Section 2326.11 & Table <br />23-1-W. Buildings shall be provided with exterior and interior braced wall lines. All braced <br />wall panels shall be clearly indicated on the plans. (Se,;t. 2326.4.1, 2326.11.3 & Table 23-1- <br />W UBC) <br />2. Update all code references on plan set to the 1994 UBC. <br />3. Provide detail of attic ventilation type, size and location. Show the required net are�� <br />calculation assuming approximately 75% of the vent area is net area unless the actual vet area <br />is given from the manufacturer. <br />4. <br />5. <br />6. <br />Provide seismic strap and pressure relief valve for water heater. <br />Chimney shall ex[end 2' above any structure within l0'-0". Show dimensions on elevations. <br />Specify the following on plans: <br />a. Grade and species of framing lumber. <br />b. Treated foundation plates. <br />c. Type a�id grade of plywood. <br />d. Design strength of concrete. <br />e. Design strength of glue-laminated timber. <br />f. Minimum reinforcing bar grade. <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 •(206) 259•8d00 • Fax (206) 259-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.