Laserfiche WebLink
Plan Check #B4G202 <br /> December 7, 1994 <br /> Page 2 of 3 <br /> ✓8. A wea[her-resistive barrier must be applied to exterior walls as specified in Section <br /> 1708(a). <br /> ✓9. Risers on stairways shall be not less than 4 inches nor exceed 7 inches, and runs (treads) <br /> shall be not less than 11 inches. Section 3306(c). <br /> f/10. The handgriP portion of handrails shall be not less than 1 inches nor more than 2 inches <br /> in cross sect�onal dimension or the shape should provide an equivalent gripping surface. <br /> 'I7�e acceptabiliry of equivalent shapes will be determined by the building official. The <br /> handgrip portion shall ha:�e a smooth surface with no sharp corners. Section 3306(i). <br /> ✓11. Handrails must have their ends returned or terminate in newel posts or safety terminals. <br /> Section 3306(i). <br /> v 12. At least one I�andrail shall extend at least 12 inches beyond the top riser and 23 inches <br /> Ueyond the bottom riser. Section 3306(i). <br /> �13. Enclosed usable space under stairs must be protected on the enclosed side as required for <br /> 1-HR fire-resistive construction. Section 3306(]). See also Section 3309(�. <br /> ��'� 14. Ramps within an accessibie route of travel shall have landings at top and bottom (and for <br /> each 30 inches of rise). Section 3106(h)4. A ramp is requ�red to each ground floor unit. <br /> 15. Top, intermediate and bottom landings shall have a dimension in the direction of rnmp <br /> : � run of not less than 60 inches. Section 3106(h)4. <br /> � 16. Surface of ramps shall be roughened or of slip-resistant materials. Section 3307(g). <br /> ✓17. Provide signage per Section 3106(p) to accessible parking space. <br /> ✓1S. Alarm svstems shall indude both audible and visible alarms and shall be located per <br /> Section 3105(d)9. <br /> /l��!'. 19. One accessible parking stall is required Section 3107(2)4. The stall size must comply with <br /> Section 3107(b). <br /> ✓20. A 30" x 48" clear floor space is required in front of each tub/shower in each ground floor <br /> unit. The 48" dime��sion must be parallel to the tub. Section 3106(22)11., Section <br /> 3106(k)9. <br /> ✓21. The entry door in each ground tloor unit must have a 5'-0" clear space measured <br /> perpendicular to the door. Section 310CQ)3.D. <br /> ✓22. Walls and floor separating dwelling units in the same building shall be of not less than 1- <br /> HR fire-resistive construction. Section 1202(b). <br /> ✓23. A 1-HR fire-resistive occupancy separation is required between storage or laundry rooms <br /> that are used in common by tenants and the rest of the building, Section 1202(b). <br />