Laserfiche WebLink
Plan Check N48876 <br /> July 31, 1995 <br /> Page 2 <br /> 4. Detail (and reference location on foundation plan) typical foundation sections <br /> for: <br /> a) Perimeter walls <br /> b) Interior bearing walls <br /> c) Depressed slabs <br /> d) Foundadon common to welling and garage <br /> e) Basement walls (parallel and perpendiculu to floor framin�) <br /> � Retaining walls <br /> 5. Call out anchor bott size and spacing on foundaaon plan or details (1806.6). <br /> Show both typical wall and shear wall condition. , <br /> 6. Regardless of the occupant load, there shall be a floor or landing on each side oi <br /> a door. Landings shall have a width not less than the width of the door/1004.9 <br /> and 1004.10 UBC. <br /> 7. Specify the header size at open�ng over 4' wide in bearing walls (2326.11.6). <br /> 8. Plans do not show how the requiremenu of the WA. State Ventilation and <br /> Indoor Air Quality Code (VIA� aze met. <br /> 9. Show slab insulation providing a thermal break. <br /> 10. Specify on the plans that insulation exposed to the exterior shall be protected <br /> and listed for thai use. <br /> 11. Source sprcific fans aze required in each Idichen, bathroom, water closet, <br /> laundry, and other rooms where excess water vapor or cooldng odor is <br /> produced. Specify fan locations and sizes per VIAQ. <br /> 12. Specify on plans which whole house ventilation system is used. Single whole <br /> house exhaust fan, combined source specific fans for whole house exhaust, <br /> integration with forced air systems or dedicated heat recovery ventilaGon <br /> system/VIAQ. <br /> 13. Outdoor air is required to be supplied to all habitable rooms for all whole house <br /> ventilation systems. Specify the type of outdoor air system including individual <br /> outdoor air inlets, forced-air heating system, ducting or equivalent mP.ans. <br />