Laserfiche WebLink
DEVCON INC. 10/31/95 <br />RE: SECOND BAPTIST ADDITION <br />C.C. CARL GIPSON, DEACON <br />ROY HARRIS, 259 8893; CITY OF EVERETT ENGINEER <br />DEAR DAVE, <br />PER YOUR LETTER OF 10/27/95: PLEASE IGNORE MY FIELD <br />ORDER OF 10/23/95 TO REDUCE THE ADDITION FROM 35' 6" <br />TO 35' 2", <br />FURTHER EXPLANATION OF THE STORM SYSTEM AS REQUESTED <br />IN YOUR LETTER OF 10/24/95: PLEASE PROVIDE A PLASTIC <br />SUMP APROX. 3' X 3' X 3' OUTSIDE THE WEST SIDE OF THE <br />ADDITION TO COLLECT STORM WATER AT THE FOOTING AREA <br />WITH THE TOP AT BASEMENT SLAB LEVEL. LOCATE AN ELEC- <br />TRIC PUMP (SIZED TO HANDLE OUR STORM WATER ONLY) IN <br />STORAGE ROOM 3 TO RAISE THE STORM WATER TO Tt1E SIDE <br />SEWER ON VIRGINIA WHEN THE SUMP FILLS TO APROX. 6" <br />BELOW THE SLAB. PROVIDE AN ALARM TO SOUND IF THE PUMP <br />FAILS. <br />LOCATE A SECOND 4" OPEN DRAIN TILE AROUND THE ADDt- <br />TION AT A HEIGHT THAT ALLOWS GRAVITY DRAINAGE INTO <br />THE SIDE SEWER. CONNECT THE ROOF DRAINS DIRECTLY <br />INTO THE SIDE SEWER. <br />OMIT THE APROX. 4' WIDE LAST BASEMENT WINDOW ON THE <br />NORTHWEST SIDE TO ALLOW POR A MECHANICAL ROOM IN THAT <br />CORNER WHICH WII.L BE COMBINED WITH STORAGE ROOM 3. <br />DETAILS WILL BE PROVIDED WHEN WE RECEIVE THE ELECTRI- <br />CAL PANEL, SPRINKLER AND PLUMBING NEEDS. <br />CHANGE REQUESTS DATED 10/25/95 AND <br />THRU 9 ARE ANSWERED ON THE ENC[,OSED <br />REQUESTS. <br />YOURS, <br />� � <br />BOB CHAMPION, AIA <br />10/26/95 N0. 1 <br />COPIES OF THOSE <br />Robert W. Champion, Architect A.I.A. <br />3802 Colby Avenue. Everett, WA 99201 (206) 259-3136 <br />