Laserfiche WebLink
COMPLIANCE <br />REQUIRED V <br />INSPECTION IMPORTANT: On NOT place checks In the two left columns. <br />APPROVED , <br />❑ ❑ W Exposed foam Insulation shall comply as follows (S. 502,1.4.7): <br />❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br />❑ Insulation is approved for sub -grade, exterior use and properly installed. <br />❑ ❑ Q6 Alrflow between fresh air ports and the whole -house fan ensured by undercut doors/gdlis(VIAQ,S. 302.6.4) <br />❑ ❑ ©i Loossflll Insulatlon OK N (S.502.1.4.5): <br />❑ maximum ceiling slope not > 3 in 12 <br />❑> 30" of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br />❑ ❑ Qe 6 mil black polyethylene ground cover, shall be lapped 12" at joints and extend to foundation wall <br />❑ ❑ n Clearances shall meet listed minimums between insulation and (S.502.1.4.3): <br />❑ chimney ❑ Non -IC rated recessed lights: 1/2" to combustables, 3" to insulation. <br />❑ ❑ o ttic hatch shall be insulated to required ceiling R-value and is weatherstripped (S.502.1.4.4) <br />❑ [] r Attic access shall have wood dam or equivalent to retain loose fill insulation in attic(S. 502.1.4.4) <br />❑ ❑ s All exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />❑ ❑ Service hot & cold water piping in unconditioned spaces shall be insulated to R-3(S. 503.11) <br />M ❑ Service recirculation hot water piping in unconditioned spaces shall be insulated (Table 5-12). <br />❑ ❑ Heat pump thermostat shall have progamable capability (S. 503.8.3.5) <br />❑ ❑4Thermostat provided for each HVAC system with range of 55-75' F.(heating) (S.503.8.1.1). <br />❑ ❑ 7 Readily accessible, automatic or Manual means provided to restrict or shut-off Heating input to <br />each zone or floor during periods not requiring heat (S. 503.8.3.1). <br />❑ ❑Jechanical <br />ntrols for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br />❑ ❑chanicai ventilation system shall have proper timers, and/or switches (VIAQ, S. 302.3). <br />E7 ❑chanical ventilation exhaust ducts in unconditioned spaces shall have R-4 ins. (VIAQ, S. 302.5) <br />❑ ❑ ventilation supply ducts in conditioned spaces shall have R-4 ins.(VIAQ, 302.5) <br />❑ ❑ pply ducts shall have volume dampers, or the equivalent, to balance system ins. (S. 503.6). <br />❑ ❑ ppiy and return air ducts shall have sealed duct joints in unconditioned spaces (S. 503.10.2). <br />❑ ❑AC plenums, supply, and return air ducts shall have R-8 insulation (Table 5-11, All options) <br />❑ p ater heater(s) shall have (S. 504.2.1. 504.3. 504.4): <br />❑ separate power, or gas shut-off ❑ 1987 NAECA Label on tank <br />❑ Elect only: noncompressible R10 pad (unheated spaces, slabs) ❑ Temperature settings 120 F. <br />❑ ❑ showers and lavatories shall limit flow to s 3.0 gallons/minute (S. 504.8.1). <br />❑ ❑ @DSwlmming pools(S. 504.5) shall have: <br />❑ readily accessible ON/OFF switch (pump, heater) ❑Pool cover ❑Piping insulated to S. 503.11 <br />❑ 0 s@a All fireplaces (VIAQ, S. 402.3) shall have: <br />❑ 6 square inch combustion air supplyduct w/ accessible damper directly Connected to the fire box <br />❑ Tight fitting glass or metal doors. 0 Tight fitting flue damper <br />❑ ❑ s Solid fuel burning appliance(s) (VIAQ, S. 402.2) shall have: <br />❑Tight fitting glass or metal doors <br />❑Outside combustion air source directly connected to the fire box <br />❑Exception: Non -direct, 4" diameter, dampered, combustion air source: allowed only for (1) new stove <br />Installations in existing homes where obstructions preclude direct combustion air, or (2) Central <br />heating systems located in unheated spaces. <br />0 ❑ o Three month, etched track radon monitor, printed instructions, and information sheets shall be <br />supplied to the single family dwelling or first floor units of multi -family dwellings by the general <br />contractor (VIAO,S. 502.2.1), <br />SEC Final phase requirements: <br />Inspected by: Date__77 <br />Page 8 <br />