My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1918 WALL ST 2018-01-02 MF Import
>
Address Records
>
WALL ST
>
1918
>
1918 WALL ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 11:40:40 AM
Creation date
3/8/2017 1:26:51 PM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
1918
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
769
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check No. 1328 <br />Byron Backstrom <br />August 24, 1983 <br />Page Five <br />19. The screen over the overflow scupper appears not to be practical. If both <br />drain and scupper are clogged a great deal of water may pond up on the roof. <br />Detail 7/A-4.2 <br />20. Portions of otherwise sprinklered buildings which are not protected by auto- <br />matic sprinklers, should have Class II standpipes installed as required for un- <br />sprinklered buildings. Table 38-A, Footnote 4 <br />21. The precast floor panels should be reviewed with respect to Research Report <br />PFC 2755 for adequate tendon cover to secure 2 hour fire resistive construction <br />for the typical floors and roof panels and 3 hour fire resistive construction for <br />floor level S-1. <br />22. Door S-203 that leads into the elevator machinery room should be 1 112 hour <br />fire protection assembly if it is a part of the elevator shaft enclosure. Table <br />17-A <br />23. The "W" well at the shaft enclosure is required to be a 2 hour wall. Two layers <br />of 5/8" of one >J de is insufficient. <br />24. hechan�cal Rooms should be separated from the I-3 occupancy by a 2 hour fire <br />resistive construction a,ith openings protected by 1 1/2 hour fire protection assem- <br />bly. Mechanical rooms 14335, 14432, M521, M522, and M523 should be separated. Wall <br />"0" does not comply for 2 hour unless alternate cel'.s are grouted. Table 5-B <br />25. The kitchen hood details should be provided. Penetration of a floor ceiling <br />system should be enclosed in a 2 hour fire resistive construction. <br />26. Glass doors and glazing immediatley adjacent to such doors should be approved <br />impact hazard glass. Section 5406(a) <br />COMMENTS ON EXITS <br />1. One of the required exits should be a smoke proof enclosure. The stairway with <br />the smoke -proof enclosure should be extended tothe roof surface. The door opening <br />at the roof should be 1 1/2 hour fire protection assembly. she penthouse over the <br />stair enclosure should be a minimum 1 hour noncombustible construction. None of the <br />3 stairs shown on the plans comply as a smoke -proof enclosure. Section 3309, and <br />3601(d) <br />*2. Two means of egress is required from every cell, multi -purpose room, and outdoor <br />recreation area. An adjoining room may be used provided such adjoining room is <br />accessory to the area served, and provides a direct means of egress to an exit cor- <br />ridor, exit stairway, exterior exit, exterior exit balcony, or exit passageway. In <br />every case, either both or at least one of the exits, must pass through more than <br />one adjoining room. Therefore, this does not comply. Section3302(e). See Sheets <br />A-3.4, A-3.5, A-3.6, A-3.7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.